19. Wrap the threads of the 1 in. MNPT x 1 in. slip PVC adaptor with thread tape and thread the adaptor in the discharge tee.
Cement as many sections and couplings of rigid 1" PVC pipe needed to connect the 1 in. MNPT slip PVC adaptor. Connect
the tank to your water system in the house.
20. This pump is pre-wired at 230 volts. If the power source is 115 volts, remove the electrical housing cover. Flip the switch
to 115 volts. Replace the cover.
NOTE: All electrical work should be performed by a licensed electrician.
21. Turn the regulator adjustment screw down tight. Turn on pump. If the pump is properly primed, a high pressure will
immediately show on the pressure gauge. With the pump operating at high pressure, slowly unscrew the adjusting screw
until maximum water flow is obtained without dropping to zero. If pressure falls completely, retighten the screw and readjust.
If no pressure shows, stop the pump, remove the pressure regulator from pump, add more water, and try again. After the
adjusted bolt is set up, lock the screw nut on the bolt. The pump is ready for use.
NOTE: The pressure regulator screw is very tight. A big screw driver needed.
15