6 STANDARD PROGRAMMING
To access the control unit programming functions, remove the
lid from the electric box and remove Jumper J4 from the bo-
ard.
1 Power Supply
When turned on, "
closed gate symbol "- - - - ".
*
If the control panel has already been programmed and the power fails or is switched off - once power is returned and a START command
is given, the position reset procedure is performed (see "rESP" in the table "WORKING STATUS MESSAGES" on page 41.
2 Motors stroke learning
ATTENTION: during the learning cycle there is no protection by the obstacles detection sensor!
1. When you remove the Jumper J4, the display will shows P003;
2. Press
button to go on with the setting;
3. As you see the message "
movements using the buttons
Attention: if the movement is not correct, switch off the
power supply, invert the motor connections and repeat the
check.
Set the door in the position of total closure;
4. Push the
button and hold it for 3 sec. (if you leave it before
3 sec., the operation will be interrupted);
5. Release the
button as soon as the "
blinking;
Set the door in open position;
7. Push the
button and hold it for 3 sec. (if you leave it before
3 sec., the operation will be interrupted);
8. Release the
button as soon as the "
blinking;
9. An opening and closing manoeuvre will follow, at normal speed;
at the end of the procedure the display will show P003.
34
NORMAL
FUNCTIONING
PROGRAMMING
MODE
", "
" (or the current firmware version) "
" blinking, verify the right door
(OPEN) and
(CLOSE);
" message start
" message start
", "
" appear on the display in sequence followed by the

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

Space xlSpace xxl

Tabla de contenido