Dea SPACE Serie Instrucciones De Uso página 28

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 99
WARNING
installation of all materials and devices which make up the complete automation
system, must comply with the European Directives 2006/42/CE (Machinery Directive),
2014/30/UE (electromagnetic compatibility), 2014/35/UE (low voltage electrical
equipment). In order to ensure a suitable level of safety, besides complying with local
regulations, it is advisable to comply also with the above mentioned Directives in all extra
European countries.
WARNING Under no circumstances use the device in an explosive atmosphere or in
areas that may be corrosive or could damage product parts. Check that the
temperatures at the installation site are suitable and comply with the temperatures
declared on the product label.
WARNING When working with the "dead man" switch, make sure that there are no
people in the area where the automatism is being used.
WARNING Check that there is a switch or an omni polar magneto-thermal circuit
breaker that enables complete disconnection in case of over voltage category III
conditions installed upstream from the power system.
WARNING To ensure an appropriate level of electrical safety always keep the 230V
power supply cables apart (minimum 4mm in the open or 1 mm through insulation)
from low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary
circuits power supply), and fasten the latter with appropriate clamps near the terminal
boards.
WARNING If the power cable is damaged, it must be replaced by the manufacturer or
its technical assistance service or, in any case, by a person with similar qualifications
to prevent any risk.
WARNING All installation, maintenance, cleaning or repair operations on any part of
the system must be performed exclusively by qualified personnel with the power
supply disconnected working in strict compliance with the electrical standards and
regulations in force in the nation of installation.
Cleaning and maintenance destined to be performed by the user must not be performed
by unsupervised children.
WARNING Using spare parts not indicated by DEA System and/or incorrect re-
assembly can create risk to people, animals and property and also damage the
product. For this reason, always use only the parts indicated by DEA System and
scrupulously follow all assembly instructions.
FORCE ADJUSTMENT WARNING:
Changing the closure force could result in hazardous situations. The closure for-
ce must therefore only be increased by qualified personnel. After adjustment, compliance
with regulatory limits values should be detected with a force impact measuring instru-
ment. The sensitivity of the obstacle detection may be adjusted gradually to the door (see
programming instructions). The anti-crushing device operation must be checked after
each manual adjustment. Manual modification of the force can only be done by qualified
personnel by performing the measurement test according to EN 12445. Modifications to
the force adjustment must be documented in the machine manual.
WARNING The compliance of the internal sensing obstacles device to requirements
of EN12453 is guaranteed only if used in conjunction with motors fitted with encoders.
26
DEA System reminds all users that the selection, positioning and

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

Space xlSpace xxl

Tabla de contenido