4. Before leaving or servicing machine:
Turn off machine.
Unplug cord from wall outlet.
5. When servicing machine:
Unplug cord from wall outlet.
Avoid moving parts. Do not wear loose
jackets, shirts, or sleeves.
Use manufacturer supplied or approved
replacement parts.
WARNING: Hazardous Voltage. Shock or
electrocution can result. Unplug machine before
servicing.
WARNING: Flammable materials can cause
an explosion or fire. Do not pick up.
GROUNDING INSTRUCTIONS
Machine must be grounded. If it should
malfunction or breakdown, grounding provides a
path of least resistance for electrical current to
reduce the risk of electrical shock. This machine
is equipped with a cord having an
equipment–grounding conductor and grounding
plug. The plug must be plugged into an
appropriate outlet that is properly installed in
accordance with all local codes and ordinances.
Grounded Outlet
Grounding
Edge/hole
3240/3260 (02–01)
Home
Find... Go To..

MACHINE COMPONENTS

(See Fig 1 on foldout page)
1. Handle
2. Attachment Tool Elbow
3. Vacuum Hose
4. Brush Housing
5. Vacuum Bag Housing
6. Brush Height Adjustment Knob
7. Brush
8. ON/OFF Switch
9. 15M Power Cord
10. Door Latch/Upper Cord Hook
11. Rear Door
12. Lower Cord Hook
13. Handle Release Foot Latch
14. Exhaust Vent
15. Rear Wheels
16. Serial Number Tag
17. Brush Circuit Breaker
(Located bottomside of brush Housing, See Fig 5)

MACHINE SETUP

1. Carefully check carton for signs of damage.
Report damages at once to carrier.
NOTE: If rear door has become misaligned during
shipment, loosen nuts at hinge, realign door and
re-tighten nuts.
2. Your Vacuum is shipped fully assembled. A paper
vacuum bag is factory installed and is ready for
operation.
Attachment Tool Kit is sold separately. If cleaning
with attachments see Attachment Tool Operation.
3. Plug power cord to wall outlet.
NOTE: This machine is suitable for voltages from
230V AC/50 Hz.
FOR SAFETY: Do not operate machine unless
cord is properly grounded.
FOR SAFETY: Do not operate machine with the
use of an extension cord.