Electrical Connection; Connection To The Heating Plant; Connections - Lincar Lola Manual Del Usuario

Ocultar thumbs Ver también para Lola:
Idiomas disponibles

Idiomas disponibles

ELECTRICAL CONNECTION

The appliance is equipped with an electrical cable H05RR-F 3x0.75 mm² having an
European plug. It is a type "Y" connection and therefore any replacement of the cable
must be carried out by a qualified staff only. Feeding 1N 230V AC 50Hz. The electrical
cable should be disposed in such a way to avoid any contact with hot and sharp parts.
The appliance should be connected with a grounding system.

CONNECTION TO THE HEATING PLANT

It's advisable to read, follow and respect what indicated in the Section Installation.
Do not use the appliance, if it has not been connected to a heating plant in working
conditions.
Before setting at work the appliance, it is necessary to fill the boiler and to eliminate
possible air bubbles.
The appliance is equipped with a closed 6 lit expansion tank. The installer must
ABSOLUTELY verify the dimensions of the heating plant and, if necessary, replace the
expansion tank with another if the equipped one should not be sufficient.
The appliance is produced with the internal working at closed expansion tank. In case the
appliance is used in pairing with other types of appliances or heating plants, the installer
should prearrange all necessary to solve compatibility problems.
The water for the heating plant should have some chemical and physical characteristics
for a good functioning of the equipment for a long time. The feeding water of bad quality
could cause problems as incrustations of the thermic exchange surfaces and sometimes
the corrosion of water surfaces of the complete circuit. The presence of chalky
incrustation penalize a lot the thermic exchange and dangerous overheating could be
caused. Here follow some examples to make treatment for water : Water hardness >
of 20°f ; Heating plant with open expansion tank; Frequent water introduction due
to lacks or maintenance operation.
Call a qualify company for the water treatment of thermic plan.
The equipment is supplied by a new generation Circulator ERP. For safe
installation and right equipment functioning, we recommend installing a Dirt
Separator with Magnet positioned on the return of the installation, upstream of the
circulator apparatus. The lack of an adequate system of filtering, could compromise
the circulator and / or its operation.
IT-GB-FR-ES mod. 540 – 540N
41/140
loading

Este manual también es adecuado para:

Malika540540n