Possible troubles and their solution
TROUBLE
CAUSE
Appliances power set to low
Boiler temperature set to low
The pre set room
temperature is not
Loss of heat.
obtained
The heating plant is too big, compared
to the power of the appliance.
The room temperature has reached the
requested value.
The appliance is
The boiler has reached the set
working at
temperature.
minimum power.
The heating plant is too small,
compared to the power of the
appliance.
Fuel of low quality.
The fuel is
Carburation/maintenance of appliance
accumulating itself
into the burner
basket.
Ashtray cover opened or not correctly
closed.
Appliance just started.
The heating plant
The room temperature has reached the
(thermo siphon) is
requested value.
tepid
The boiler temperature has reached
the set value.
Any repairs must be carried out by an authorized after-sales service or
qualified staff.
Attention: Disconnect always the appliance before making any intervention.
CORISIT S.r.l. is not responsible for damages to thing or people due to a wrong installation,
equipment tampering, improper use, bad maintenance or no observation of normative in
force. If considerate appropriate, CORISIT S.r.l. reserves the right to make modifications
without notice and in every moment.
Some particulars and accessories illustrated in this handbook are not mass produced item so
its extra costs are to check at contract release.
IT-GB-FR-ES mod. 540 – 540N
SOLUTION
Increase the power.
Increase the boiler temperature
Improve the plant and house
insulations.
Reduce the dimension of the plant.
Set up a higher temperatur.
Set up a higher boiler temperatur.
Increase the dimension of the plant.
Improve the quality of the fuel.
Effect Cleaning by User and/or
ordinary maintenance. Effect a pellet
correction (menu09).
Verify if the ashtray cover is correctly
closed.
Wait until the appliance has reached
the normal working range.
Set up a higher room temperature.
Set up a higher boiler temperature.