Preliminary operations
Take away the packing
Before installation, check the appliance integrity. In case of doubt, do not use the
appliance and call the dealer.
Packing materials is for recycle, getting it in the specify container
Appliance positioning
The installation room should have :
A suitable floor for appliance weight. Should the existing construction not satisfy this
requirement, necessary measurements must be taken (I.e. a plate for the distribution of the
weight)
A suitable floor for appliance calorific radiation, which grants against fire risks.
The installation of the appliance should grant an easy access for the cleaning operations of
the appliance itself, as well as of gas exhaust ducts and of the chimney.
A minimal distance from flammable materials (see security distances)
The room must be continuously ventilated according to the local rules.
− It's prohibited to install the equipment into sleeping rooms, bathroom or where another
heating equipment ( without an independent air supply ) is just installed.
− It's prohibited product positioning in environments with explosive atmosphere

FLOOR PROTECTION

The equipment must be installed on a non–combustible surface. In case of flammable floor (as
wood, moquette, etc.) is necessary to prepare a protective base of the floor (sheet steel,
ceramic or other) with the following dimensions:
Hold up in front ≥ 500 mm;
Hold up back

SECURITY DISTANCES

From NOT combustible object :
A > 500 mm B > 100 mm C > 100 mm D > 1000
From combustible object and from principal wall in reinforced concrete :
A > 1000 mm B > 200 mm C > 200 mm D > 1000
The minimal distance between the appliance and every objects over it
must be at least 1 meter.
Mod. 540
≥ 100 mm
Mod. 540N
40/140
IT-GB-FR-ES mod. 540 – 540N
Hold up lateral ≥ 300 mm;