Inserting the oven into the cabinet
The cabinet and its components must be capable of withstanding
a temperature of 90°C without presenting any deformation and/
or surface defects. The cabinet must enable the free passage
of the oven connections. All household kitchen units must be
protected with fire-resistant material in accordance with the
standards in force.
It is important that all operations relating to installation of
the device are carried out by qualified staff. The oven can be
installed in a column or below the worktop of a kitchen cabinet.
INSTALLATION CLASS - 3
ATTENTION
Respect minimum ventilation apertures of the cabinets, as
given in the drawings.
ATTENTION
In order to guarantee good ventilation, the aperture of
80 mm is also recalled towards the outside of the cabinet
and not only in the rear part, otherwise application is not
compliant..
Fig. 01
30
Fig. 02
Built-in measurements
The dimensions of the opening to be made in the cabinet for
fitting the oven are indicated in figures. Make sure that the
cabinet where the oven is installed can support the weight of
30 kg. For the aperture in the cabinet, follow the respective
dimensions indicated in fig.01, fig.02 for FI-64, FI-74. In the
bottom of the cabinet or in the oven support shelf, to allow
sufficient air to circulate for the cooling of the oven during
functioning.
Use screws A for fixing the oven.