sheath must be connected in the relevant terminal.
WARNING: The electrical connections must be carried out workmanlike
by qualified experienced personnel, in conformity with all the current
standards and with the use of appropriate materials.
Lay out the electrical installation with reference to the current electrical
standards.
Keep the mains supply connections clearly separated from the service
connections.
In the initial section of the electrical installation, fit a circuit breaker with
a contact opening distance equal to or greater than 3,5 mm, provided
with magnetothermal protection and a differential switch having ad-
equate capacity for the appliance consumption. For the wiring, only
use cables conforming to the harmonised or national standards, having
a cross section corresponding to the initial protection, the appliance
consumption and the installation conditions, for example a 3x1.5 sq
mm (H 05 VV-F) cable.
TERMINAL DESCRIPTION
1-2
Control for cooling fan 230V~ ±10% (1=L) (2=N)
3-4
Not used
6-7
Motor connections
15-5
Motor connections, closing reference
15-8
Motor connections, opening reference
9-10
Flashing light (24 V~, 25W)
Accessories power supply:
24 V operation with mains power on.
11-12
24 V (11+,12-) operation with no mains power and optional
buffer battery kit.
Safety device power supply output (photocell transmitter).
N.B.: output active only during operating cycle.
13-14
24 V Vsafe operation with mains power on.
24 V (13+,14-) Vsafe operation with no mains power and
optional buffer battery kit.
START button (N.O.)
15-16
This option can be set via the "logic menu".
Start - operation according to 2-3-4 step logic.
STOP input (N.C.)
15-17
The command stops movement.
If not used, leave jumper inserted.
PHOTOCELL input (N.C.).
15-18
Operation according to photocell during opening logic.
If not used, leave jumper inserted.
19
Safety device test input FAULT - PHOT (N.O.).
SAFETY EDGE input BAR (N.C.).
The command reverses movement during closing and stops
15-20
movement during opening.
If not used, leave jumper inserted.
Barrier-open warning light output (N.O. contact, 24V~/ 3W max)
21-22
or, in alternative, alarm output (see Table "B", Alarm SCA) and
Connection To Parky Car-Park Management System
23-24-
Encoder inputs
25-26
OPEN/ TIMER control button (N.O.)
Open - Gate opened with this command.
15-27
Timer - If the contact is closed, the leaves open and stay open
until the contact is opened. If the contact connected is open,
the leaves close and are ready for normal operation.
Close button CLOSE (N.O.)
15-28
The command causes the leaf to close.
15) SAFETY DEVICES FIG. H
Note: only use receiving safety devices with free changeover
contact.
15.1) NON-TESTED DEVICES FIG. H1
15.2) TESTED DEVICES FIG. H2, H3
16) ADJUSTMENTS
RECOMMENDED ADJUSTMENT SEQUENCE:
Adjusting the limit switches Fig.I (
Programming remote controls
Setting of parameters/logic, where necessary
17) PARAMETERS MENU (para )
(TABLE "A" PARAMETERS)
18) LOGIC MENU (logic)
26
- GIOTTO 30-50 S BT / GIOTTO 30-50 BT
INSTALLATION MANUAL
)
See reference section
https://appceso.com
(TABLE "B" LOGIC)
19) RADIO MENU (RADIO)
Logic
Description
Add Start Key
add start
associates the desired key with the Start command
Erase List
WARNING! Erases all memorized remote controls
erase 64
from the receiver's memory.
Read receiver code
Displays receiver code required for cloning remote con-
cod RX
trols.
ON = Enables remote programming of cards via a previously me-
morized W LINK transmitter. It remains enabled for 3 minutes
v
from the time the W LINK remote control is last pressed.
OFF=W LINK programming disabled.
- IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST
BE IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the first transmitter assigns the
RECEIVER'S KEY CODE: this code is required to subsequently clone the
radio transmitters.
The Clonix built-in on-board receiver also has a number of important
advanced features:
• Cloning of master transmitter (rolling code or fixed code)
• Cloning to replace transmitters already entered in receiver
• Transmitter database management
• Receiver community management
To use these advanced features, refer to the universal handheld pro-
grammer's instructions and to the CLONIX Programming Guide, which
come with the universal handheld programmer device.
20) DEFAULT MENU (default)
Restores the controller's default factory settings.
21) LANGUAGE MENU (language)
Used to set the programmer's language on the display.

22) STATISTICS MENU

Shows:
- board version
- number of total manoeuvres made by the automation
- number of remote controls saved to the built-in receiver
23) CONNECTION TO PARKY CAR-PARK MANAGEMENT SYSTEM
The board can be configured in order to make an output available for
controlling the barrier status. When the SCA Alarm logic is disabled (OFF)
and the Alarm Time parameter is set to 0 s, the SCA contact (21-22) is
configured as follows (Fig. G):
- contact closed between terminals 21-22 with the barrier lowered
- contact open between terminals 21-22 with the barrier lifted
23.1) SERIAL CONNECTION USING SCS1 BOARD (Fig. AE)
The LIBRA-C-G/LIBRA-C-GS control panel allows several automation
units (SCS1) to be connected in a centralised way by means of appropri-
ate serial inputs and outputs. This makes it possible to use one single
command to open and close all the automation units connected.
Following the diagram in Fig. AE, proceed to connecting all the LIBRA-C-
G/LIBRA-C-GS control panels, exclusively using a telephone-type line.
Should a telephone cable with more than one pair be needed, it is
indispensable to use wires from the same pair.
The length of the telephone cable between one appliance and the
next must not exceed 250 m.
At this point, each of the LIBRA-C-G/LIBRA-C-GS control panels must
be appropriately configured, by setting a MASTER unit first of all, which
will have control over all the others, to be necessarily set as SLAVE (see
logic menu).
Also set the Zone number (see parameter menu) between 0 and 127.
The zone number allows you to create groups of automation units, each
one answering to the Zone Master unit. Each zone can only be assigned
one Master unit, the Master unit in zone 0 also controls the Slave
units in the other zones. WARNING: the control panel set as the master
must be the first in the series.
23.2) Opposite Barriers (Fig. AF)
By means of a serial connection, it is also possible to obtain centralised
control of two opposite barriers/gates.
In this case, the Master M1 control panel will simultaneously manage
closing and opening for the Slave M2 control panel.
SETTING REQUIRED FOR OPERATION:
- MASTER board: zone=128, aster=ON
- SLAVE board: zone=128, aster=OFF
WIRING REQUIRED FOR OPERATION:
- The MASTER and SLAVE control units are interconnected through the