performing a complete opening and closing cycle and the Deceleration
cycle is set automatically too at approximately 15% of the complete
cycle;
• Press the SET button to memorize the motor stroke.
During Automatic Programming, instead of the SET key on the control unit
you can use the button on the remote, providing the remote has been
saved beforehand.
Important notes:
- In the event that the motors move in a manner other than that described:
• Disconnect the power supply to the control unit.
• Change the position of Dip Switch SW2 to change the drive direction to
the desired motor without physically using the electrical connections.
- During Automatic Programming, the radio control button (if previously
memorised) may be used instead of the control unit SET button.
- It is not possible to carry out Automatic Programming in the absence of
limit switches and/or encoders wired to the control unit.
8.2 EXTENDED MENU 1
The control unit is factory set to allow direct selection exclusively of the main
menu functions. If you wish to enable the functions described in Extended
Menu 1, proceed as follows:
• Select blinking LEV LED and press SET once;
Press SET once;
• The LED will start blinking (alternate flashing of LEV LED
);
In this way you have access to the setting of the following functions:
L1
HOLD-TO-RUN
ON
"PEDESTRIAN BUTTON /
SINGLE DOOR
L2
SINGLE LEAF
PP/OPEN
PPED/CLOSE"
L3
PEDESTRIAN BUTTON / DS3
DS3
L4
PHOTOTEST
ON
L5
DS2 STOP IN CLOSE
ON
L6
DS1 PARTIAL INVERSION
ON
L7
BLOCK / 8K2
ON
LEV
MENÙ
There will be 30 seconds to select the functions of the Extended Menu
1 using the SELECT and SET keys; once an additional 30 seconds have
elapsed the control unit reverts to the main menu.
8.2.1. LED L1 - HOLD-TO-RUN:
The control unit allows you to configure the "Dead Man Switch" function. In
this way, using the radio controls and the buttons to send a command, the
following operation will be obtained: it will be necessary to keep the desired
command all the time activated (button pressed constantly) to obtain the
movement of the gate. When you release the command, the gate will stop
immediately. If this mode of operation is desired, proceed as follows.
The control unit allows setting the "Deadman" operation. To enable this
operation mode, proceed as follows:
• Make sure you have enabled the extended Menu 1 (as shown by the
alternate flashing 1 0 1 0 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L1;
• Press the SET key;
• LED L1 becomes steady on and programming will be completed.
In this way, using both the remote controls and the shutter activation
Buttons, the following operation will be obtained: it is necessary to keep
the desired command constantly activated (button pressed constantly) to
obtain the movement of the door of the shutter. The release of the control
will cause the stroke to stop immediately.
Repeat the procedure if you wish to restore the previous configuration.
8.2.2. LED L2 - SINGLE LEAF OR PP. BUTTON = OPEN, PED. BUTTON
= CLOSE:
The control unit allows a N.O. Pushbutton to be connected (CN2 input no.
10) to activate the gate in Pedestrian Opening mode.
It is however possible to use this input to connect a N.O. pushbutton
operating in a different manner.
If you wish to enable the "Single Leaf" function, proceed as follows:
• The LED will start blinking (alternate flashing 1 0 1 0 1 0 of LEV LED);
• Select blinking LEV LED and press SET once;
• Press the SET key;
• By the key SELECT, position yourself on the blinking LED L2;
In this mode the PPED button can be used to operate only Motor 1.
In contrast, if you wish to enable "OPEN-CLOSE" mode in order to use
the Pedestrian Pushbutton to activate exclusively closing of the gate
and the P/P Pushbutton to (CN2 input no. 11) to activate exclusively
opening of the gate, repeat the operation described above, pressing
the SELECT key twice (LED L2 will blink rapidly) instead of just once.
Repeat the procedure if you wish to restore the initial configuration.
8.2.3. LED L3 - PEDESTRIAN PUSHBUTTON / DS3:
The control unit allows a N.O. Pushbutton to be connected (CN2 input no.
10) to activate the gate in Pedestrian Opening mode.
However, this input can be used to connect a DS3 photocell (N.C):
• Select blinking LEV LED and press SET once; The LED will start blinking
(alternate flashing 1 0 1 0 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L3;
• Press the SET key;
• LED L3 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the initial configuration.
8.2.4. LED L4 - PHOTOTEST (Photocells test):
The control unit is factory set with the photocells test disabled.
Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 1 (as shown by the
alternate flashing 1 0 1 0 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L4;
OFF
• Press the SET key;
• LED L4 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
PEDESTRIAN BUTTON
8.2.5. LED L5 - DS2 STOP IN CLOSE:
PEDESTRIAN BUTTON
The control unit allows the operation of input DS2 to be modified. If you
want DS2 to trip also during closing (stopping of the gate leaf, then once
OFF
the passage is free, the gate resumes the closing manoeuvre) proceed as
OFF
follows:
OFF
• Make sure you have enabled the extended Menu 1 (as shown by the
alternate flashing 1 0 1 0 1 0 of LEV LED);
OFF
• By the key SELECT, position yourself on the blinking LED L5;
• Press the SET key;
1 FLASH
• LED L5 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.2.6. LED L6 - DS1 PARTIAL INVERSION:
The control unit allows the operation of input DS1 to be modified. If, during
a closing manoeuvre, you want DS1 to perform a partial reversal (short
reversal) of the gate leaf instead of a total reversal, proceed as follows:
• Make sure you have enabled the extended Menu 1 (as shown by the
alternate flashing 1 0 1 0 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L6;
• Press the SET key;
• LED L6 becomes steady on and programming will be completed
Repeat the procedure if you wish to restore the previous configuration.
8.2.7. LED L7 - BLOCK = 8K2:
The control unit allows the connection of an N.C. Emergency Stop
pushbutton (CN2 input no. 8). However, to switch this input to an 8.2
KOhm resistive input proceed as follows:
• Make sure you have enabled the extended Menu 1 (as shown by the
alternate flashing 1 0 1 0 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L7;
• Press the SET key;
• LED L7 becomes steady on and programming will be completed.
From this moment on, the connection of a resistive edge to the control unit
in the relative input will result in the colour change (from red to green) of the
STOP / 8K2 led.
A change in the input value causes a partial inversion and the subsequent
block of the control unit in any phase of the leaf stroke.
Repeat the procedure if you wish to restore the previous configuration.