5.5 CONDOR 500 / CONDOR 500 S - connection diagram of the motors
DELAY OF THE MOTOR no.2
1
CONDOR 500
SW1
ON
1
2
2
DELAY
MOTORS
MOT. 2
DELAY OF THE MOTOR no.1
1
CONDOR 500
SW1
ON
1
2
2
DELAY
MOTORS
MOT. 1
Wire connection of motors WITHOUT ENCODER to the control unit
Configuration - MOTEUR 1 À GAUCHE, MOTEUR 2 À DROITE
Motor line connection to control unit
MOTOR # 1 (left)
BLACK in OP1
BLUE in CM1
BROWN in CL1
CN1
2
DIP1 ON = 2 motors configu-
ration
DIP2 OFF = Delay of motor no. 2
2
DIP1 ON = 2 motors configu-
ration
DIP2 ON = Delay of motor no. 1
1
CONDOR 500 S
SW2
ON
1
2
INV
INV
OFF
MOT. 2
1
CONDOR 500 S
SW2
ON
1
2
INV
INV
OFF
MOT. 2
MOTOR # 2 (rights)
BLACK in OP2
BLUE in CM2
BROWN in CL2
COMUNELLO ®Copyright 2019 - All right reserved
2
DIP1 OFF = inversion MOTOR
no. 1 disabled
DIP2 ON = inversion MOTOR no.
2 enabled
2
DIP1 OFF = inversion MOTOR
no. 1 disabled
DIP2 ON = inversion MOTOR no.
2 enabled