The third menu is the one defined as EXTENDED 2 and to access the programmable functions follow the instructions given in Tab. 4:
EXTENDED
• Press the SELECT button and scroll the LED menu until
MENU 2
you reach the LEV LED;
• Press SET twice to access the EXTENDED menu 2.
LIVEL 2 - EXTENDED MENU 2
LED
FUNCTION
L1
BRAKE
Enabling of the electronic
brake
L2
STEP BY STEP 1
Step-By-Step logic
L3
ALWAYS CLOSE
Enables the sending of a
CLOSE command when the
power is turned on again
L4
FOLLOW ME
The motor automatically
closes in 5 sec after passing
through DS1 photocell
L5
PEDESTRIAN TIME
Storage of motor no.1 partial
stroke with slowdowns
L6
2°CH MONOSTABLE /
Setting the aux. relay of the
BISTABLE/TIMED MONO.
2°CH as Bistable / Monosta-
ble /Temporised monostable
L7
REMOTELY PROGRAMMING
Enable the remote control
memory function without
acting on the control unit
Table 4
The fourth and last menu is defined as EXTENDED 3 and to access the programmable functions follow the instructions given in Table 5:
EXTENDED
• Press the SELECT button and scroll the LED menu until
MENU 3
you reach the LEV LED;
• Press SET 3 times to access the EXTENDED menu 3.
LIVEL 3 - EXTENDED MENU 3
LED
FUNCTION
L1
SOFT STOP
Setting of gradual slowdown
at the end of the movement
L2
SOFT START
Setting of gradual slowdown
at the beginning of the
movement
L3
RELEASE STROKE MAX
Activation of the push in ope-
FORCE/ RELEASE STROKE
ning for electric lock release
L4
SLAM LOCK MAX FORCE /
Activation of the push in clo-
SLAM LOCK
sing for electric lock release
L5
ELS / CMD PED
Activation of the electric lock
as PPED input
L6
LAMP / L.CORT L.SPIA /
Flashing light set as pilot light
LAMP L.CORTESIA
or courtesy light
L7
PRELAMP / LAMP IN PAUSA
Activation of the pre-flash for
3 s. before the CLOSE cycle /
Flashing in pause time
Table 5
ATTENTION: The control unit allows to be programmed if all the safety devices (N.C. inputs on terminals) grant a contact closed.
7 DETAILED
DESCRIPTION
FUNCTIONS
7.1 ELECTRICAL CONNECTIONS
L:
230 V~ Line input (Phase)
N:
230 V~ Line input(Neutral)
LAMP 230~:
Flashing Light Output 1 (230 V~ Neutral)
LAMP 230~:
Flashing Light Output 1 (230 V~ Phase)
MOT1 OPEN:
Operator 1 opening output
MOT1 COM:
Operator 1 output common
MOT1 CLOSE:
Operator 1 closing output.
MOT2 OPEN2:
Operator 2 opening output
MOT2 COM2:
Operator 2 output common
MOT2 CLOSE2:
Operator 2 closing output
CN2:
DESCRIPTION
Always enabled
Open-Stop-Close-Stop (It DOESN'T close after the pause
time in a partial opening phase)
Enabled function
Enabled function
Partial stroke of motor no.1 stored
Bistable command
Enabled function
DESCRIPTION
Enabled function
Enabled function
Enabled function at the max
FORCE
Enabled function at the max
FORCE
Enabled function
Flash. → Courtesy light
Preflash in CLOSE
OF
ALL
il LED della funzione LEV LAMPEGGIA con questa frequenza:
LED ON
Always enabled
Disabled function
Disabled function
Disabled function
10 sec., without slowdowns
Temporized 3 min.
Monostable command
(impulsive)
Disabled function
The LED of the LEV function FLASHES with this frequency
LED ON
Disabled function
Disabled function
Enabled function - FORCE
Disabled function
trimmer
Enabled function - FORCE
Disabled function
trimmer
Disabled function
Flash. → court. light.; Pilot
Flashing light
light → Flash.
Fllash in pause time
Disabled function
2nd CH: Aux Radio CH Output (Free Contact max load 30V DC 1A)
2nd CH: Aux Radio CH Output (Free Contact max load 30V DC 1A)
FOTO +
Photocell control and power supply
LAMP 24V
Signal light output 24Vac
GND
Common GND input
DS2
Safety device input 2 (NC)
DS1
Safety device input 1 (NC)
STOP 8K2
Block / 8K2 input
GND
Common GND input
P PED:
Ingresso Puls. Pedestrian/Single Door/open button input
(NO)
PP:
Open-close/close command button input (NO)
ELS +
Electric lock output +24Vdc
ELS -
Electric lock output -
24V 5W
Services output (+24Vdc)
GND:
Common GND input
SPIA+24V LED:
Output indicator lamp (+24 V / 4 W)
ANT-:
Chassis ground input (sheath)
COMUNELLO ®Copyright 2019 - All right reserved
LED OFF
DEFAULT
LED OFF
DEFAULT
37