Comunello Automation QUAD - 230V - HP Instrucciones De Uso página 27

Tabla de contenido
1 ELECTRICAL CONNECTIONS (WIRING DYAGRAM)
Flashing light
230V 500W
LINE
POWER SUPPLY
2P+T 230V 50Hz.
230Vca
FUSE 1:
Aliment.
T15A 250V
CN1
CN5
CN4
FUSE 2:
T10,5A 250V
Primary
Second.
Transf.
Transf.
DIP SWITCH SW1
The SW1 Dip-Switches allow you to select the 1 or 2 motor
which second.
SW1
SW1
SW1
ON
ON
ON
1
2
1
2
1
2
1
NOT
2
MOTOR
2
MOTOR
MOTOR
CONSID.
MOTORS
2 DELAY
MOTORS
1 DELAY
DIP SWITCH SW2
The SW2 Dip-Switches allow to change the direction of stro-
ke of each motor without physically intervening on the electri-
cal connections in the terminal block.
SW2
SW2
SW2
SW2
ON
ON
ON
ON
1
2
1
2
1
2
1
INV
INV
INV
INV
INV
INV
INV
OFF
OFF
MOT 1
OFF
OFF
MOT 2
MOT 1
MOT 2
CAUTION: DS1, DS2 and STOP/8K2 are bridged by the factory. To connect the photocells, the stop button and the edge sensors, it is
necessary to remove the jumper from the terminal.
Motor output
2x 50W 50Hz
CN3
TRIMMER SENS: It regulates the SENSITIVITY of motors
TRIMMER FORCE: It regulates the FORCE of motors
2
INV
TRIMMER SLOWING: It regulates the slowdown speed of motors
Encoder
Limit Switch M2
Motor 2
FCA-Open FCC- Closed
Encoder
Motor 1
Limit Switch M1
FCA-Open FCC- Closed
CN2
2nCH
N.A. output aux radio channel. (30V 1A)
2nCH
FOT+
24Vcc Power supply (5W)
L24V
GND
DS2
DS1
S8K2
GND
PPED
PP
ELS+
ELS-
24V
GND
+LED
ANT-
ANT+
Schielding
Pole
Turning with a screwdriver towards the + increases the sensitivity
and therefore the motor will block its stroke more quickly if an ob-
stacle is detected.
Turning with a screwdriver towards the + increases the motor
force.
speed during deceleration in 3 STEPS
Vel.Min.
Vel.Med.
Vel.Max.
COMUNELLO ®Copyright 2019 - All right reserved
N.C. Photocells
DS2 input
N.C. Photocells
DS1 input
STOP input/8K2
input for resistive
hedges
N.O. Step-by-step input
N.O. Pedestrian input
12Vcc Electric lock output
+ 12Vcc (max 5W)
GND
+ 24Vcc (max 4W) Indicator light
Antenna Cable
27
Tabla de contenido
loading

Tabla de contenido