Safety
Only qualified licensed installers should carry out installation,
initial start-up, maintenance and repair of the water heater.

8.1 General safety instructions

Use only original accessories and spare parts intended for this
water heater.
DANGER Electric shock
Disconnect the water heater from the power supply
prior to its installation.
WARNING Injury
If the pipes inside the water heater are damaged,
leaking refrigerant gas can result in severe physical
freezer burns.
Do not inhale refrigerant. Immediately vent the room
thoroughly.
» Wear safety goggles and gloves during water heater
installation.
WARNING Injury
Moving parts represent a risk of injury.
» Before opening the water heater, ensure that the fan
has come to a complete standstill.

8.2 Incorrect use

The following are not permitted:
- Do not install the water heater on non-load bearing floors
- Do not install the water heater where it is at risk from frost
- Do not install in rooms where the water heater is at risk from
explosions as a result of dust, gases or vapors
- Do not ignore safety clearances and safety zones
- Do not incorrectly install the power connection
- Do not operate the water heater with the tank empty
- Do not operate the water heater with an open casing
- Do not heat anything other than potable water
- Do not fill with any other Freon, use only R134A

8.3 Qualification

WARNING Injury
Incorrect handling can result in severe injuries and
material losses. Inadequately qualified personnel
cannot assess the impending danger.
Have only personnel mentioned in the appropriate
sections of this manual carry out specific measures.
In this manual, such qualified individuals will be described as the
"licensed installer".
Licensed installers are responsible for adherence to all currently
applicable regulations during installation and initial start-up.
8.3.1 Licensed installer
Licensed installers are specially trained in their field. Licensed
installers work on systems on the basis of their training, knowledge
and experience, as well as their knowledge of applicable standards
and regulations. They are able on their own to recognize and
prevent possible problems.
WWW.STIEBEL-ELTRON-USA.COM
8.3.2 Electrician (licensed)
An electrician is a licensed installer who meets the above
requirements with regard to electrical installations.
8.3.3 Plumber (licensed)
A plumber is a licensed installer who meets the above requirements
with regard to water-related installations.
8.3.4 Customer service
For customer service inquiries, please contact Stiebel Eltron
directly at 1-800-582-8423, ext. 25 or ext. 33.

8.4 Instructions, standards and regulations

Follow all national, state, and local codes.
Observe the regulations of your local energy and water supply
utilities.
The following standards were taken into account:
UL 499, UL 1995, UL 94-5 VA, UL 174
IEC 60335-1-2-40, IEC 61000-3-2; 1995
IEC 61000-3-3, IEC 55014-1 IEC 55014-2
EMC Directive 89/336/EEC
EN 255 T3
Read the water heater type plate and the chapter "Specification".

8.5 Water installation

The following materials may be used:
- Cold water line: steel, copper or plastic pipework.
- Hot water line: copper or plastic pipework.
» Ensure that no contamination reaches the water heater
through the pipework.

8.6 Electrical installation

Protect the water heater electrically with a 15 A double pole circuit
breaker.
Where the water heater is permanently connected to the power
supply, it must be able to be separated from the mains power
supply by an additional isolator that disconnects all poles with
at least 3 mm (0.12 ") contact separation. For this purpose, use
contractors, circuit breakers, fuses, etc. on site.
In case of a fault, the safety equipment interrupts the relevant
power circuit.