Descaling; What To Do If; The Water Heater Does Not Deliver Hot Water; The Safety Valve Of The Cold Water Supply Line Is Dripping - Stiebel Eltron ACCELERA 300 Manual De Operación E Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

OPERATION

WHAT TO DO IF ...

1
1
Condensate pan drain

6.1 Descaling

At high temperatures water separates out lime. This is deposited
on the inside of the tank. With increasing limescale build-up, the
amount of hot water inside the tank is reduced.
» Have a licensed installer descale the booster heater from
time to time. This extends the service life of the booster
heater.
» Scale cannot build up on the heat pump element.
A licensed installer who knows the local water quality will tell you
when the next maintenance appointment is due.
» Have your licensed installer check the sacrificial anode
regularly.
7.
What to do if ...
7.1
... the water heater does not deliver hot
water
» Check the water heater power supply.
» Check your fuse box for a tripped circuit breaker.
» Make sure there is a 15 A double pole circuit breaker
If the circuit breaker has tripped, reset it or replace it. Notify your
local licensed installer if the circuit breaker trips again.
» Ensure that the air intake and air discharge are unobstructed.
Excessively high ambient temperature, excessively high
temperature of the air drawn in (> 42 °C (108 °F)) or a fault in the
refrigerant circuit can result in the compressor being overloaded.
The thermal protective 'auto reset' motor switch or the high limit
'manual reset' cut-out can both shut off the compressor off.
The high limit pressure limiter must only be reset by
your licensed installer after they have removed the
cause of the relevant fault.
After a short cooling down period, the thermal protective motor
auto reset switch will restart the compressor automatically.
Notify your local licensed installer if the water heater does not
restart automatically.
12
| ACCELERA® 300 HEAT PUMP WATER HEATER
7.2
... the safety valve of the cold water supply
line is dripping
This unit can operate up to 0.48 MPa (70 psi) of inlet pressure.
Expansion water drips from the safety valve during heat-up. This
is completely normal. Notify your local licensed installer if water
still drips after heat-up has been completed.
7.3

... the condensate drain drips

This is quite normal and always happens when the surface
temperature of the evaporator is lower than the dew point
temperature of the ambient air.
7.4

... the power consumption is too high

Please consult a qualified licensed installer.
7.5

... the room temperature drops excessively

The water heater operation reduces the ambient air by
1 to 3 °C (2 to 6 °F). Notify your local licensed installer if the
ambient temperature drops abnormally.
7.6

... other faults occur

Notify your local licensed installer. Refer to the water heater
number on the type plate next to the barcode.
Type: Accelera 300/WHP 300
Order-No.: 222423
Observe the installation manual! Tested for leaks!
1
Water heater number
No.:
xxxx / xxxxxx
Made in Germany
WWW.STIEBEL-ELTRON-USA.COM
1

Capítulos

Tabla de contenido
loading

Tabla de contenido