GENERAL INFORMATION
WARNINGS AND NOTES
Electronic weighing is a method of precise measurement.
Security must remain at the forefront, please follow the
instructions in this manual to increase the longevity of your
device and ensure good long term results.
platform scales have a zone of overload. It must be
observed to avoid damages of the sensor and to
prevent a loss of warrantee (balance gives a warning
signal up to 135% overload)
Ensure that the weight placed on the scales is stable.
Check that all screws, rods and brackets are secure
Do not weigh in case of extreme humidity and rain
Avoid working at high ambient temperatures
Allow the balance to recharge every 2-3 months for
at least 24 hours to ensure maximum capacity and
longevity.
Please carefully read the instructions!
TECHNICAL DETAILS
Model
SBS-
SBS-
SBS-
SBS-
BW-
BW-
BW-
BW-
3T
5T
1T
3T/
1KG
Measuring
up to
up to
up to
up to
3000
5000
1000
3000
range
kg
kg
kg
kg
Division
1 kg
2 kg
500
1 kg
g
EN
Dead weight
119
151
79
57 kg
kg
kg
kg
Weighing
150 cm | 150
100 cm | 100 cm
cm
surface
Functions
Hold
Tare
Zero
Parts counting
Change the weight units (kg/lb)
PACK
Display
LCD
Model
SBS-
SBS-
SBS-
BW-3T
BW-5T
BW-1T
Measuring
up to
up to
up to
range
3000
5000
1000
kg
kg
kg
Division
1 kg
2 kg
500 g
Dead weight
119 kg
151 kg
79 kg
Weighing
150 cm | 150 cm
100 cm | 100 cm
surface
Functions
Hold
Tare
Zero
U S E R M A N U A L
Functions
Parts counting
Change the weight units (kg/lb)
PACK
Display
LCD
Model
SBS-
SBS-
SBS-
BW-
BW-
BW-
5T/2KG
1T/0.5A
3T/1A
Measuring
up to
up to
up to
range
5000
1000
3000
kg
kg
kg
Division
2 kg
500 g
1 kg
Dead weight
82 kg
52 kg
99,0 kg
Weighing
100 cm | 100 cm
150 cm | 151,5 cm
SBS-
surface
BW-
Functions
Hold
5T/
2KG
Tare
up to
Zero
5000
kg
Parts counting
2 kg
Change the weight units (kg/lb)
PACK
82 kg
Display
LCD
CONTROL PANEL
1
2
3
4
1.
Button „C"
2.
Button „HOLD"
SBS-
3.
Button „PACK"
BW-
4.
Button „UNIT"
3T/1KG
5.
Button „PCS"
up to
6.
Button „ZERO TARE"
3000 kg
KEY FUNCTIONS
Warning signals and state
1 kg
Battery Level (lb)
If your balance shows LB and produces a beep at the
57 kg
same time or the display gradually goes out, the battery is
discharged. Connect the scale on the sector. The LB display
and the beep tone stop, and the AC LED will turn on. To fully
charge the battery, let the scale¬load for 4h.
BUTTONS AND OPTIONS
With the switch I/O on the back of the device, you can turn
the scale on.
6
A self-test starts. It begins with a test of the screen and
the diodes. The screen should display 0.0.0.0.0.0. and all
the LEDs should light. Then the information on the current
calibration values is displayed (from the factory: 0150.05:
0150 stands for 150kg and 0.5 for the measurement
interval), as well as the programmation of the calculator
(Uer_3, 2 for ver3,2) and the state of the battery (eg. dC_U5,
0 for 5.0 V) After the test, the scale is ready to use when
SBS-
it displays 0.00. Press the button I / O again to turn off
BW-
the scale.
5T/2A
up to
For the SBS-BW-3T/1KG scale model, the connection
5000
between the scale head and the scale platform is wireless.
kg
The communication between the head and the platform is
being established right after switching on the scale head
2 kg
and the scale platform. The scale platform is equipped with
three control lights:
AC – means that the storage battery of the platform
98,5 kg
is charging (AC power is connected)
Low Voltage – means that the platform storage
battery needs to be charged
SIGNAL – after proper wireless connection between
the scale head and the scale platform this light will
be blinking.
If the scale display will show „Err24", it means that there
is wireless connection error (the platform is off or the
platform storage battery needs to be charged).
TARE (ZERO)
Before weighing, make sure that ZERO and STABLE
indicators are on the left and the desired unit is on the
right. This means the optimum state of operation of the
device. If the ZERO indicator is not turned on or the display
is not showing zero after taking off the load from the scale,
then the key [ZERO/TARE] must be pressed. The scale will
confirm the tare showing 0.00. The weight window will
display the net weight value.
ERROR MESSAGES ( SBS-BW-3T, SBS-BW-5T, SBS-BW-1T,
SBS-BW-3T/1KG, SBS-BW-5T/2KG )
"Ad_Err" – The weight cannot be measured by the
sensor. Necessary repairs.
"Lo_bat" – Charge the battery
5
6
--- --- OL Overload. – Too much weight on the scale
Seterra – The internals data are not correct.
Necessary repairs.
DO NOT PRESS THE BUTTON ( ZERO / TARE )
until the weight is not stable, (ie until the LED STABLE is not
lit) to avoid measurement errors.
TARE (ZERO)
To tare, place an empty container on the platform when the
STABLE LED is lit. Then press (ZERO / TARE) for the scale to
ignore the weight of the container.
CAUTION
After the tare, the maximum capacity is reduced by the
weight of the container! Eg container b = 90kg, normal max
weigh s= 150kg Max. capacity Left: s-b = 60kg. Immediately
remove the weight in case of overload! OL ---- (----)
HOLD ( HOLD )
If the weight is superior to 0.05 kg in weighing mode, the
save mode can be activated by pressing the HOLD button.
Rev. 27.09.2018
Rev. 27.09.2018
At the same time, the HOLD LED lights up as a confirmation.
Press the HOLD key again to exit the hold mode and to
return to the weighing mode.
UNIT CHANGE ( UNIT/KG/LB, LB/KG )
With the (UNIT) key, you can change units between lb and
kg. Press the button (UNIT) to choose the right unit.
PACK FUNCTION
There are 2 selections under PACK function: IN & OUT. The
default setting is "NO", which means ALARM and PACK
functions in non-work status; When it is under IN, it will
alert between UPPER and LOWER limit; When it is under
OUT setting, it will alarm that the weight exceeds the
upper limit or below LOWER limit. It shows HHHHHH when
exceeding UPPER limit and LLLLLL when below LOWER limit.
HOW TO SET IN
put the preset weight (e.g. 1000.0g), keep pressing [PACK]
and the indicator shows SET-AL; then the scale enter into
choosing function mode. Press +/- for enter into mode
IN. Press [ZERO/TARE] to confirm and then enter into next
setting; The indicator shows AL-UP, then enter into LOWER
limit set(e.g. input 995.0g). Press [ZERO/TARE] to confirm
and go for next step;
The indicator shows AL-DN, then enter into UPPER limit
(e.g. input 1005.0g). Press [ZERO/TARE] for confirmation
and the indicator shows IN. It means the setting is finished
when the indicator keeps alarming.
Note: [IN] range between 1000.0g±5.0g is an example for
customer's references.
HOW TO SET UPPER/LOWER LIMIT
[UNIT] and [HOLD] could be used to set upper & lower limit
by inputting the numbers 0-9 into the setting. Press [UNIT]
to increase and [HOLD] to decrease. Press [ZERO/TARE] to
confirm and quit setting.
SETTING OF ALARM
When indicator shows IN, it will alert the weight is between
UPPER and LOWER limit. When window shows OUT, it will
alert the load exceeds the UPPER limit or below LOWER
limit. When window shows NO, it means it will not alarm
without any load. Press [TARE/ZERO] to confirm the current
selection.
HOW TO SET OUT
Put the preset weight (e.g. 1000.0g), keep pressing [PACK]
and the indicator shows SET-AL; then the scale enter into
choosing function mode. Press +/- for enter into mode
OUT. Press [ZERO/TARE] to confirm and then enter into
next setting; The indicator shows AL-UP, then enter into
UPPER limit set(e.g. input 1005.0g). Press [ZERO/TARE] to
confirm and go for next step. The display will show AL-DN
and the LOWER limit should be set (e.g. input 995.0 kg).
Press [ZERO/TARE] to confirm and then the display will
show the 1000.0 kg. This means that settings are finished.
Exceeding the lower limit (995.0 kg) is indicated by a beep
and displaying (LLLLLL) on the display. Exceeding the upper
limit is indicated by a beep and displaying (HHHHHH) on
the display.
PARTS COUNTING
Setting the average weight of the sample
Turn on the scale and wait for weighing mode. Put the
samples on the platform - number of the samples must be
10/20/50/100/200/500/1000.
7
EN
loading