6 Care and maintenance
CAUTION
In order to avoid inadvertent ejection of mortar, re-
move the foil pack before beginning to clean the tool.
6.1 Care of the tool
CAUTION
Keep the tool, especially its grip surfaces, clean and
free from oil and grease.
Clean the outside of the tool at regular intervals with a
slightly damp cloth.
7 Troubleshooting
Fault
The trigger cannot be pressed.
The foil pack does not open
automatically.
Trigger movement is very stiff.
The foil pack holder cannot be
pivoted and pushed all the way
down into the tool.
The foil pack holder does not
engage with an audible click.
8 Disposal
CAUTION
Improper disposal of the equipment may have serious consequences: The burning of plastic components generates
toxic fumes which may present a health hazard. Careless disposal may permit unauthorized and improper use of the
equipment. This may result in serious personal injury, injury to third parties and pollution of the environment.
Lubricate the piston rods with oil when necessary. Mortar
adhering to the tool or the foil pack holder must be
cleaned off with a cloth before it hardens. Hardened
mortar can be removed only by mechanical means. Take
care to ensure that the tool is not damaged by cleaning.
Do not use a spray, steam pressure cleaning equipment
or running water for cleaning. Never dip or soak the tool
or its parts in solvents. Check that the piston moves freely
in the foil pack holder.
6.2 Checking the tool after care and maintenance
After carrying out care and maintenance, check that mov-
ing parts function faultlessly, that no parts are sticking,
broken or damaged and that the tool operates faultlessly.
Possible cause
The foil pack holder has not fully en-
gaged.
The mortar in the mixing nozzle has
hardened.
The advance mechanism is defective.
The tool has reached the end of its
life.
The foil pack is too cold.
The trigger pressure is too high for
the tool.
The foil pack is not pushed all the
way into the holder.
The piston rods are not pulled back
fully.
The retaining lugs are dirty / clogged.
The retaining lugs are defective.
Remedy
The foil pack holder must engage fully
with an audible click.
Press the release button. Change the
mixing nozzle.
Replace the tool.
Replace the tool.
Raise the temperature of the foil pack
(observe the instructions for use of
the foil pack).
Use the right tool for the job.
Push the foil pack into the holder as
far as it will go.
Press the release button and pull the
piston rods back as far as they will
go.
Clean the retaining lugs and engage
the foil pack holder fully.
Replace the foil pack holder. Contact
Hilti Service if the problem persists.