Periodic Checks; Opening The Casing; Replacing The Batteries; Technical Data And Characteristics - Cointra CPA 11 Instrucciones De Uso, Instalación Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
CPA
connections facing down.
IF THE ABOVE INSTRUCTIONS ARE NOT OBSERVED THE-
RE MAY BE RISK OF SUFFOCATION OR POISONING DUE
TO GAS OR FUMES ESCAPING; DANGER OF FIRE OR EX-
PLOSION. ALSO, THERE MAY BE RISK OF FLOODING THE
ROOM
3.2.2 Checks during operation
• Light the unit.
• Make sure the fuel and water systems are tight.
• Check the efficiency of the air and flue gas ducts while the heater is operating.
• Make sure the gas valve modulates correctly.
• Verify that the heater ignites easily. Turn it on and off several times to make sure.
• Check that the fuel consumption is as indicated.
3.3 MAINTENANCE

3.3.1 Periodic checks

In order for the unit to operate correctly, an authorized technician must perform an annual
inspection, checking that:
• The control and safety devices (gas valve, etc.) operate correctly.
• The exhaust vent is perfectly efficient.
• The air and flue gas ducts and terminal are free of obstacles and leaks.
• The burner and exchanger are free of dirt and deposits. Do not use chemicals or steel
brushes to clean them.
• The electrode is free of deposits and properly positioned.
• The gas and water systems are perfectly tight.
• The gas delivery and operating pressure values are as indicated on the tables.
A soft, damp cloth may be used to clean the casing and exterior parts of the heater, using
soapy water if necessary. Do not use abrasive detergents or solvents.

3.3.2 Opening the casing

To open the casing:
1. Unscrew the A screws.
2. Rotate the casing.
3. Lift the casing.
Before performing any operations inside the heater, close the gas
cock.
fig. 14 - Opening the casing

3.4 REPLACING THE BATTERIES

To change the batteries, proceed as described in fig. 15.

4 TECHNICAL DATA AND CHARACTERISTICS

4.1 Dimensions and connections

Model
A (mm)
11
330
14
400
=
fig. 16 - Dimensions and connections
1
1/2" gas inlet
2
1/2" cold water inlet
3
1/2" domestic hot water outlet
Rev. 00 - 11/2018
fig. 15 - Opening the battery box
B (mm)
C (mm)
D (mm)
E (mm)
170
550
585
220
650
685
1
3
2
53 53
A
B
a4
106
B
=
EN
a4 (mm)
570
110
670
130
185
27
Tabla de contenido
loading

Este manual también es adecuado para:

Cpa 11 14Cpa s 14lCpa s 11l

Tabla de contenido