Acquisition Function (Datalogger) - Promax TV EXPLORER II Manual De Instrucciones

Explorador universal de tv
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

USER'S MANUAL. TV EXPLORER II/II+
The TV EXPLORER II / II+ allows directly changing the tuned channel pertaining
to the active channel plan by means of the horizontal cursors [6]
way, once selected the channel-tuning field
MEASUREMENTS
[12] operation modes is possible to check cyclically the entire
active channel list.
NOTE:
The icon
equipment is carrying out an internal operation and user must wait to
complete it.

5.10 Acquisition function (DATALOGGER)

The Datalogger function allows the user to carry out and store measurements in a
fully automatic way. It can store for each acquisition the measurements made in different
points of the installation. The measurements made are relevant to the current analogue
or digital channel, in the active channel plan.
To select the Datalogger function, activate the UTILITIES
select the RUN DATALOGGER option. Later, by turning the rotary selector [1] select a
previously stored acquisition or a NEW DATALOGGER.
9/38
TEST POINT:
CHANNEL SET:
FREQ:
CH:
DVB-T/H. MPEG-2. MEASURING...
CANCEL
During analogue channel measuring process, a percentage counter appears at the
bottom of the screen showing the percentage of channel measurement done. In the case
of digital channels, appears a timer showing time left to finish in seconds. At the top left
corner appears the channel being measured followed by the total amount of channels in
the current channel plan.
12/2013
[24] and in the TV
in the upper corner of the screen indicates that the
PINEMALLCTR
PREMISE1
STATION1
482.00
MHz
C/N:
-1
kHz
POWER:
22
MER:
CBER:
VBER:
Figure 12.- DATALOGGER screen.
key. From this
[10] and
[22] menu and
22.7
dB
<52.4
dBµV
3.5
dB
4.7E-2
1.7E-5
16 Sec.