Attenuation Test Function - Promax PROLITE-65 Manual De Instrucciones

Medidor de potencia óptica y comprobador ftth
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4.2.2 ATTENUATION TEST Function

This function shows on screen in a simple and concise way the attenuation (dB)
on a fibre optic installation in the three most common wavelengths of data transmission
(1490, 1550 for Downstream and 1310 for Upstream) for this type of installations. These
data are essential to certificate fibre optic installation.
To access this function:
1.-
Press CONFIG
2.-
Press
3.-
Press SEL
To make a proper measurement with this function, first you have to capture the
reference values. To do this you should use the PROLITE-65 with a calibrated
wavelenght generator (PROLITE-105) through a reference optical fibre. Then you have
to capture the new reference values pressing UP
simultaneously for one second. Now you can make measurements on the optical fibre
at the installation. For a practical application refer to the appendix.
a) Wavelenght at which measurements are taken. Wavelenght 1310 nm
corresponds to Upstream and the other two (1490 and 1550 nm) corresponds
to Downstream.
b) Absolute power loss of the signal at the corresponding wavelenght. It
represents the measurement of the power loss or signal attenuation in dB.
Page 14
[2].
or
[5] until pointing at ATTENUATION TEST.
[4] or CONFIG
Figure 6.- ATTENUATION TEST Screen.
USER'S MANUAL. PROLITE-65
[2] to get into this function (see figure 6).
and DOWN
07-2010
Tabla de contenido
loading

Tabla de contenido