3.1.
Maximum input values
Function
A AC, D CA
V DC, V AC
Resistance, diode, continuity test,
frequency, work cycle, capacity
Temperature (°C/°F)
4. Specifications
4.1. DC Volts
Ranges
400mV
4
V
40
V
400
V
600
V
Overload protection: 600V AC/DC
Input Impedance:
4.2. AC Volts
Range
400 mV
4
V
40
V
400
V
600
V
Overload protection: 600 V AC/DC
Frequency range:
Input Impedance:
4.3. DC Current
Range
40 A
400 A
Overload protection: 400 A
Resolution
100 µV
1 mV
10 mV
100 mV
1
V
10 MΩ
Resolution
100 µV
1 mV
10 mV
100 mV
1
V
50/60 Hz
10 MΩ
Resolution
10 mA
100 mA
Max. Input
400 A
600 V DC/AC
250 V DC/AC
250 V DC/AC
Accuracy
0,8% rdg. + 2 dgt.
1,5% rdg. + 2 dgt.
2,0% rdg. + 2 dgt.
Accuracy
1,0% rdg. + 10 dgt.
1,5% rdg. + 5 dgt.
2,0% rdg. + 5 dgt.
Accuracy
2,5% rdg. + 5 dgt.
2,8% rdg. + 5 dgt.
-24-