Variable speed motors and geared motors
1.4 - Wiring diagram

1.4.1 - Standard configuration (factory setting)

MAINS
SUPPLY
Terminals
Specifications
+10 V analogue source
1
Rated current: 3 mA
Analogue reference input
2
0 to +10 V or 4-20 mA
Analogue output 0 to +10 V
Rated current: 3 mA
3
0 V = zero speed
10 V = max. speed
4
0 V - common with terminal 6
Ramp selection logic input
5
1s (50 Hz) = terminals 5 and 6 not connected
3s (50 Hz) = terminals 5 and 6 connected
6
0 V - common with terminal 4
Logic input
7
run reverse/stop
Logic input
8
run forward/stop
Relay output 250 V - 1A
9 - 10
PARAMETER-SETTING MANUAL
VARMECA 10
GENERAL INFORMATION
L1
L2
L3
PE
9
Fault
relay
10
Switched off or faulty
On
1
+10V
Local button or
2
external potentiometer
3
0-10V speed image output
4
0V
5
Ramp selection
6
0V
7
Run reverse / stop
8
Run forward / stop
Associated parameter setting
Reference
K4
Local button
OFF
External
potentiometer or
ON
external 0-10 V
4 -20 mA
ON
reference
Setting other parameters
see sections 2 and 3
Ref. 3264 - 4.33/b -1.00