LEROY-SOMER
Variable speed motors and geared motors
1.4.3 - Configuration option 2: analogue reference and 3 preset speeds - 1 operating direction
MAINS
SUPPLY
Terminals
Specifications
+10 V analogue source
1
Rated current: 3 mA
2
Analogue input reference
Analogue output 0 to +10 V
Rated current: 3 mA
3
0 V = zero speed
10 V = max. speed
4
0 V - common with terminal 6
5-8
Logic inputs S1- S2
6
0 V - common with terminal 4
Logic input
7
run forward/stop
Relay output 250 V - 1A
9 - 10
PARAMETER-SETTING MANUAL
VARMECA 10
GENERAL INFORMATION
L1
L2
L3
PE
9
Fault
relay
10
Switched off or faulty
On
1
+10V
External potentiometer or
2
external reference
3
0-10V speed image output
4
0V
S1
5
Preset speeds
6
0V
7
Run/stop
8
Preset speeds
S2
Associated parameter setting
CDC-VMA
PEGASE VMA 10
Terminal block configuration
P14 = 2
P16 = VP1-2(Hz)
VP1 OPTION 2(Hz)
P17 = VP2-2(Hz)
VP2 OPTION 2(Hz)
P18 = VP3-2(Hz)
VP3 OPTION 2(Hz)
MINI DIP K4 = ON
Reference Mini DIP K1
0 - 10 V
4 - 20 mA
Reference
S1
VP1-2
0
VP2-2
1
VP3-2
0
Analogue
1
reference
Setting other parameters
see sections 2 and 3
Ref. 3264 - 4.33/b -1.00
OPTION 2
ON
OFF
S2
1
0
0
1
33