6600
The instruction manual is downloadable from
the site www.vimar.com
INSTALLATION RULES.
Installation should be carried out observing current
installation regulations for electrical systems in the
Country where the products are installed.
CONFORMITY.
EMC directive
Standards EN 61000-6-1, EN 61000-6-3.
INFORMATION FOR USERS UNDER DI-
RECTIVE 2012/19/UE (WEEE)
In order to avoid damage to the environ-
ment and human health as well as any ad-
ministrative sanctions, any appliance marked with
this symbol must be disposed of separately from
municipal waste, that is it must be reconsigned to
the dealer upon purchase of a new one. Appliances
marked with the crossed out wheelie bin symbol
must be collected in accordance with the instruc-
tions issued by the local authorities responsible for
waste disposal.
DESCRIPTION:
Monitor with "open voice" twin channel and 3,5''
colour LCD screen. The monitor screen may be
vertically sloped.
PUSH-BUTTONS AND ADJUSTMENTS
A)
Flat 3,5" LCD screen.
B)
Microphone
C)
Loudspeaker
D1-D2)
Pair of push-buttons:chime choice /
lighting adjustment
E1-E2)
Pair of push-buttons: chime volume /
contrast adjustment / volume adjustment
audio line
F)
Command function F1
G)
Command call to the switchoboard or
door lock (when monitor is called)
H)
Command function F2. In alternative it is possi-
ble to program the push-button as function F3
or F4 or F5. The push-button
as F3 or F4 or F5 operates in cyclical way, i.e.
each pressure of push-button changes func-
tion.
I)
Push-button talk / listen, for conversation
enabling. After the call and/or switch-on of the
monitor, hold the push-button down for conver-
sation with the speech unit.
L)
LED Sign for external activation
M)
Led indicator for chime exclusion / vari-
ous programmings
TERMINAL BLOCK
1)
Digital call line
2)
Secondary entrance panel audio line
3)
Audio line
4)
Negative line
5)
+ 13,5V DC line
6)
Inserted monitor signalling (for additional
chimes or other services)
7)
Monitor negative line
8)
Monitor positive line
9)
Line for outside door call.
VIMAR group
10) Supply voltage for video floor distributor
11)
F1 - connection for auxiliary functions, to
be connected if indicated on the diagram.
12)
F2 - connection for auxiliary functions, to
be connected if indicated on the diagram.
13)
Supply voltage for green LED indicator
V1)
Input for the video signal
M)
Video earth
V3) Video signal input for cable other than coaxial
PROGRAMMING THE NUMBER/CALL CODE
With monitor switched off, operate as it follows:
Press simultaneously and hold the "I" and "H"
push-buttons.
Wait for 3 seconds until the red led "M" starts flash-
ing.
Release both push-buttons "I" and "H" and press
the "G" push-button within 5 seconds for at least 3
seconds until the red LED "M" is steadily lit. Now the
device is on programming mode and can receive the
number to code from an entrance panel or from the
programmer Art. 950B. At the code reception and
after a correct programming, the red led M switches
off and the device returns to the basic mode.
OUTDOOR CALL
Through a dedicated terminal cabling it is possible
to discriminate the call tone coming from an outdoor
push-button (for example passage, secondary entry
etc.) from that coming from an outdoor station.
Terminal 9 is preset for the input of the call wire for
an apartment entrance panel (the speech unit Art.
930D) or for a simple push-button N.A. (connected
between 9 and 5) which make the monitor ring
through a programmed chime. On receiving an
apartment outdoor call it is possible to turn the moni-
tor on and send a digital command able to switch
the video signal in the entrance with that of a possi-
ble camera on the apartment door. To do so you
must enable the monitor switching on (from outdoor
call unit by pressing the "D1" and "E1" push-buttons,
being the monitor switched off, until the red led "M"
flashes and then pressing the "H" push-button) and
choose the command to route (by pressing the "E1"
and "E2" push-buttons (with monitor off) until the led
M flashes and press then the push-button corre-
sponding to the function,
"UNANSWERED CALL" FUNCTION
By means of an external entrance panel this type
of function allows the user to signal his absence to
the calling visitor; it may also be used when the user
is at home, but does not want to answer. When the
function is enabled the video-interphone receiving
programmed
the call does not emit an acoustic signal, but sends
a "USER ABSENT" command to a possible switch-
board and, in addition, makes the "M" red LED flash
as many times as the ananswered calls (max 4). To
enable this function, it is enough to press and hold
the "D1" and "E1" push-buttons (with monitor off)
until the led M lights up, then press the "I" push-but-
ton; the Led "M" will light up and remain ON to show
the function is active.
To disable this function, with monitor off, press and
hold the "D2" and "E2" push-buttons until the led M
lights up and then press the "I" push-button; the led
switches off.
CHOOSING THE RING TONE
With monitor off, press push-button "D1" or "D2"
for nearly 5 seconds to choose the ring tone for the
entrance panel call; when the first ring tone sounds
you can scroll all the ring tones by pressing several
times "D1" or "D2".
To choose the outdoor call ring tone, (always with
monitor off) press "D1" and "D2" simultaneously
for nearly 5 seconds until the red led "M" flashes
intermittently; now press "D1" or "D2" to choose the
ring tone.
CHIME EXCLUSION
To adjust the chime volume, with monitor off press
"E1" or "E2" for at least 5 seconds until the chime
associated with the entrance panel starts ringing.
Now increase or decrease the volume by pressing
the "E1" or "E2" push-button respectively. You can
get the chime exclusion by pressing continuously
the "E2" push-button until the red led "M" switches
on.
SELECTING THE VIDEO INPUT
The double switch on the rear of monitor (fig. 1 for
6624 und fig. 2 for 6724) selects the input video
signal: for the coaxial type cable or for the double
cable.
VIDEO ADJUSTMENT
The colour adjustment is carried out by a trimmer
on the rear of monitor (fig. 1 for 6624 und fig. 2 for
6724). The brightness and contrast adjustment is
made with monitor on and by two digital trimmers
pressing the "D1", "D2" and "E1", "E2" push-buttons
respectively.
AUDIO ADJUSTMENT
To adjust the audio volume, (during a conversation)
press the "E1" or "E2" push-button together with the
"I" push-button.
C H O O S I N G
OPERATION (
As default the pressure of push-button H routes the
F command to the digital BUS.
With the following procedure it is possible to change
the operation making the push-button lose its corre-
spondence to "F2" and adquiring the F3, F4, F5
functions in a cyclical way. To enable the F3, F4
and F5 functions press and hold down (with monitor
off) the D1 and E1 push-buttons at the same time
until the red led M flashes, press then the F
push-button (
ble the F3, F4, F5 function (the one set as default)
press the D2 and E2 push-buttons at the same time
until the red LED M flashes, now press the F
push-button (
,
.
OPERATION
Monitors type 6624, 662D, 6724 must be used only
on digital Digibus type ELVOX video-interphone
installations; for the supply voltage use only the digi-
bus range power supplies (for example type 6948).
The digibus system allows you to carry out installa-
tions with digital type device and command identifi-
cation. According to the installations configuration,
each device connected is identified by a 4 or 8
univocal numerical code and it is able to receive and
send a data packet containing all the information
related to the communication management; in fact
each data packet includes the identification of the
destination device and the command to be carried
out. All typical command operations of a video-inter-
phone system, such as call, electrical lock release,
stair-light switching on etc., are then codified.The
audio and video signals are, on the contrary, analog-
ical type signals.
EN
T H E
" H "
P U S H - B U T T O N
)
); the red LED M turns off. To disa-
) ; the red LED M turns off .
5