To end sensor setting
Highlight EXIT and turn the Shuttle dial clockwise.
The previous display will be restored.
REC CYCLE and DURATION values of pre-
alarm recording
HSR-X200
REC CYCLE
Selectable DURATION values
0.02
2s/3s/5s/10s/20s/40s/1m/2m/3m/4m/5m/10m/15m
0.03
3s/5s/10s/20s/40s/1m/2m/3m/4m/5m/10m/15m
0.05
5s/10s/20s/40s/1m/2m/3m/4m/5m/10m/15m
0.07
5s/10s/20s/40s/1m/2m/3m/4m/5m/10m/15m
0.10
10s/20s/40s/1m/2m/3m/4m/5m/10m/15m
0.13
10s/20s/40s/1m/2m/3m/4m/5m/10m/15m
0.17
10s/20s/40s/1m/2m/3m/4m/5m/10m/15m
0.20
20s/40s/1m/2m/3m/4m/5m/10m/15m
0.23
20s/40s/1m/2m/3m/4m/5m/10m/15m
0.27
20s/40s/1m/2m/3m/4m/5m/10m/15m
0.30
20s/40s/1m/2m/3m/4m/5m/10m/15m
0.33
20s/40s/1m/2m/3m/4m/5m/10m/15m
0.37
20s/40s/1m/2m/3m/4m/5m/10m/15m
0.43
0.50
0.60
0.70
0.80
0.90
1.00
HSR-X200P
REC CYCLE
Selectable DURATION values
0.02
2s/3s/5s/10s/20s/40s/1m/2m/3m/4m/5m/10m/15m
0.04
3s/5s/10s/20s/40s/1m/2m/3m/4m/5m/10m/15m
0.06
5s/10s/20s/40s/1m/2m/3m/4m/5m/10m/15m
0.08
5s/10s/20s/40s/1m/2m/3m/4m/5m/10m/15m
0.12
10s/20s/40s/1m/2m/3m/4m/5m/10m/15m
0.16
10s/20s/40s/1m/2m/3m/4m/5m/10m/15m
0.20
20s/40s/1m/2m/3m/4m/5m/10m/15m
0.24
20s/40s/1m/2m/3m/4m/5m/10m/15m
0.28
20s/40s/1m/2m/3m/4m/5m/10m/15m
0.32
20s/40s/1m/2m/3m/4m/5m/10m/15m
0.36
20s/40s/1m/2m/3m/4m/5m/10m/15m
0.40
0.44
0.52
0.60
0.68
0.76
0.84
0.92
1.00
40s/1m/2m/3m/4m/5m/10m/15m
40s/1m/2m/3m/4m/5m/10m/15m
1m/2m/3m/4m/5m/10m/15m
1m/2m/3m/4m/5m/10m/15m
1m/2m/3m/4m/5m/10m/15m
1m/2m/3m/4m/5m/10m/15m
1m/2m/3m/4m/5m/10m/15m
40s/1m/2m/3m/4m/5m/10m/15m
40s/1m/2m/3m/4m/5m/10m/15m
40s/1m/2m/3m/4m/5m/10m/15m
1m/2m/3m/4m/5m/10m/15m
1m/2m/3m/4m/5m/10m/15m
1m/2m/3m/4m/5m/10m/15m
1m/2m/3m/4m/5m/10m/15m
1m/2m/3m/4m/5m/10m/15m
1m/2m/3m/4m/5m/10m/15m
Alarm Recording Procedure
When the specified trigger is detected, recording
automatically begins.
Recording is executed with the conditions specified
with ALARM REC MODE SET on the alarm
recording area.
Each time alarm recording is made, the alarm count on
the monitor increases by one.
The value returns to 1 when it exceeds 9999.
When you set pre-alarm recording to ON, the HSR-
X200/X200P immediately starts pre-alarm recording
when you exit the menu, and continues recording the
camera input, overwriting the data in the alarm
recording area for the specified duration. When the
trigger is detected, it starts regular alarm recording.
During pre-alarm recording, the indicator of the
ALARM button lights.
It flashes during alarm recording.
When the alarm recording area becomes full
If overwriting of the alarm recording area has been set
to OFF, a warning message will appear on the monitor
screen when the remaining capacity drops to the
specified value (1% with the default). At the same
time, the ALARM FULL indicator flashes, and a
warning signal is output from the ALARM FULL
terminal on the rear panel.
The overwriting ON/OFF setting and the value of the
remaining for warning can be changed with
RECORDING CONDITIONS SET of MAIN
MENU 1.
For details, see page 51(GB).
Note
If the trigger is detected when normal recording is in
progress, alarm recording will be executed without
interrupting normal recording.
27
(GB)