If the appliance is in Stand-By-Mode, it is put in Operating-Mode by pressing
successful operation acoustically.
On all heaters a ´0` appears and all Decimal Point of the heater flashes (1
sec on, 1 sec off).
If there is no operation within 10 sec, the display of all heaters will turn off.
If the displays are turned off, the heater will be set into Stand-By-Mode.
If
is pressed more than 2 sec (in Operating-Mode), the appliance is
switched off and is set into the S-Mode again. The appliance can be turned
off by pressing
at any time; even if other buttons are pressed
simultaneously.
If there is a residual heat of a heater remaining, this will be indicated in the
correspondent heat setting Heater Display.

Select Heater

If a single heater is chosen with the corresponding Active/Deactive Heater
Button
, the Decimal Point of the related Heater Display flashes. For the
Heat Setting Buttons
The buttons must be pressed within 3 sec, otherwise the heater selection
is erased and heat setting dot will disappear (Decimal Point). If there is no
further operation within 10 sec, the heater falls back into the S-Mode.
The heat setting can always be changed by pressing
level 1-9.
Each button operation or each display change is quitted by a buzzer signal.