INDEX
Declaration by manifacturer ..........................1
OVERVIEW.......................................................7

1 PRODUCT CONFORMITY..................................7

2 RESIDUAL RISK WARNINGS ............................7
3 MODELS AND CONTENTS OF THE PACKAGE...8
4 OPERATING INSTRUCTIONS ...........................8
4.1
Product description................................8
4.2
Technical data........................................8
4.3
Labelling information............................8
4.4
Appropriate conditions of use ..............8
4.5
Instructions for risk-freeoperation ........9
4.5.1 Transport – 9
4.5.2 Installation, assembly
and disassembly – 9
4.5.3 Starting – 9
4.5.4 Use – 9
4.5.5 Adjustment – 9
4.5.6 Maintenance and repair – 10
4.6
Training ...............................................10
4.7
Inappropriate use................................10
5 SPARE PARTS LIST..........................................10
6 COMPLETE CLOSING ASSEMBLY ...................10
6.1
Minimum level of protection
provided by the safety edge................10
6.2
Crushing in the opening area .............10
6.3
Impact in the opening/closing area ....10
Example of typical installation ............27
ANNEXES
- Instructions for the final user
- Terms of warranty
OVERVIEW
SCOPE OF THE INSTRUCTIONS
These instructions were prepared by the manufacturer and
are an integral part of the product. The operations described
are intended for adequately trained and qualified operators and
must be carefully read and conserved for future reference.
Chapters "2 RESIDUAL RISK WARNINGS" and "4 OPERA-
TING INSTRUCTIONS" contain all the information that DEA
System provides in order for the product to constantly satisfy
the Essential Safety Requirements prescribed by the Machinery
Directive (European Directive 98/37/CE). Read these chapters
carefully because they contain important instructions for safe
installation, use and maintenance and important warnings re-
garding the residual risks remaining even after all the safety de-
vices and measures described have been applied. The product
is designed for installation in complete closing systems subject
to specific legislation. Chapter 6 "COMPLETE CLOSING ASSEM-
BLY" provides useful information for the respect of the Essential
Safety Requisites for special types of closing.
1
PRODUCT CONFORMITY
The LIVI 400 gate operator bears the CE label. DEA System
guarantees the conformity of the product to European Directives
98/37/CE regarding machinery safety, 89/336/CE and amen-
dments regarding electromagnetic compatibility and 73/23/CE
and amendments regarding low voltage electrical equipment.
Operating instructions and warnings
DEA System also encloses the manufacturer's Declaration of
Conformity with these instructions (see Directive 98/37/CE Art.
4, paragraph 2).
2 RESIDUAL RISK WARNINGS
Read these warnings carefully; the failure to respect the fol-
lowing warnings can create risk situations.
WARNING The use of the product under unusual conditions
not foreseen by the manufacturer can create situations of dan-
ger, and for this reason all the conditions prescribed in these
instructions must be respected.
WARNING Under no circumstances must the product be
used in explosive atmospheres or surroundings that may pro-
ve corrosive and damage parts of the product.
WARNING All installation, maintenance, cleaning or repair
operations on any part of the system must be performed
exclusively by qualified personnel with the power supply
disconnected working in strict compliance with the electrical
standards and regulations in force in the nation of installation
WARNING All other adjustment/setting operations beyond
the adjustment of the limit switch cams and of the mechanical
clutch are made by the manufacturer. Tampering with these
settings may cause malfunction and/or situations of risk to
people, animals and property. Refrain from performing any
operations not authorised by DEA System.
WARNING The use of spare parts not indicated by DEA Sy-
stem and/or incorrect re-assembly can create risk to people,
animals and property and also damage the product. For this
reason, always use only the parts indicated by DEA System
and scrupulously follow all assembly instructions.
WARNING Awareness of the operation of the key-release
mechanism (see F9 Page 32) is essential for all users of the
automatism because the failure to use the device quickly
during emergencies can jeopardise people, animals and pro-
perty. Enclosure I to these instructions, which the installer is
required to deliver to the final user, illustrates operation and
can be detached.
WARNING DEA System reminds all users that the selection,
positioning and installation of all materials and devices which
make up the complete automation system, must comply with
the European Directives 98/37/CE (Machinery Directive),
89/336/CE and subsequent amendments (electromagnetic
compatibility), 73/23/CE and subsequent amendments (low
voltage electrical equipment). In order to ensure a suitable
level of safety, besides complying with local regulations, it is
advisable to comply also with the above mentioned Directives
in all extra European countries.
WARNING To ensure an appropriate level of electrical safety
always keep the 230V power supply cables apart (minimum
4mm in the open or 1 mm through insulation) from low volta-
ge cables (motors power supply, controls, aerial and auxiliary
circuits power supply), and fasten the latter with appropriate
clamps near the terminal boards.
WARNING Any external safety device installed in order to con-
form to the limits set for impact forces must comply with EN12978.