Troubleshooting Table - Dea LIVI 400 Instrucciones De Uso

Ocultar thumbs Ver también para LIVI 400:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

The LIVI 400 is designed for installation in sliding gates as
an actuator for the operational automatism as shown in F3 on
Page 31. Brackets for both "horizontal" (standard) and "vertical"
(see "PRODUCT ACCESSORIES" table) installation have been
arranged for. The LIVI 400 has been designed and tested for
operation under "normal" civil gate opening conditions; tem-
perature limits, degrees of protection against dust and water,
and other data are provided in Point 4.2 "Technical Data". Sa-
tisfactory operation requires the correct positioning of the LIVI
400 operator with respect to the gate; DEA System recommen-
ded measurements are shown in F3 page 31. The automatism
required must be selected according to the gate to be moved;
the attrition on the attachments, the weight, the length/height of
the gate wing, and the degree of closing of the surfaces are the
elements to be considered.
WARNING The use of the product under unusual conditions
not foreseen by the manufacturer can create situations of dan-
ger, and for this reason all the conditions prescribed in these
instructions must be respected.
WARNING Under no circumstances must the product be
used in explosive atmospheres or surroundings that may prove
corrosive and damage parts of the product.
4.5
Instructions for risk-free operation
4.5.1 Transport
The LIVI 400 gate operator is always delivered packed in
boxes that guarantee the product adequate protection. Carefully
read any warnings or instructions for storage and handling pro-
vided on the box.
4.5.2 Installation, assembly and disassembly
The following operations are essential to the correct laying
of the product:
• The careful definition of the entire automatic opening layout
(see also paragraph "6 Complete Closing Assembly");
in particular, after carefully assessing the characteristics
of the place you have selected, define model and correct
positioning of the foundation base (see F3, pages 31);
• screw in the foundation base (see F8 page 32) or put it in
concrete with item nr. 460;
• Check carefully the correct positioning of the foundation
base;
• Screw LIVI 400 and the foundation base together using
appropriate screws (see F7 page 32);
MALFUNCTION
When the opening or closing
command is activated the gate
leaf fails to move and the opera-
tor's electric motor fails to start.
When the opening command
is activated, the motor star-
ts but the gate leafs fail to
move
The gate moves by fits and
starts, it is noisy, it stops at
half run or it does not start
Operating instructions and warnings
"TROUBLE-SHOOTING" table
The operator is not receiving correct power supply. Check all connections, fuses, and the
power supply cable conditions and replace or repair if necessary. If the gate does not close
check the correct functioning of photocells.
Check that the unlocking system is closed (see F9, page 32)
Check the electronic force adjustment device and the mechanical clutch
ake sure that the motor does not push in the opposite direction, the limit switch electrical
connections might be reversed
Make sure that nothing hinders the gate wheels movement and the slide in which they roll;
There always must be backlash between rack and pinion; make sure the rack is accurately
positioned.
The power of the gearmotor may be insufficient for the characteristics of the gate's wing;
check the choice of model whenever requiredh
If the operator attachment to the gate bends or is badly fastened, repair and/or buttress it.
WARNING All installation, maintenance, cleaning or repair
operations on any part of the system must be performed exclu-
sively by qualified personnel with the power supply discon-
nected working in strict compliance with the electrical standar-
ds and regulations in force in the nation of installation.
4.5.3 Starting
The installation of the product requires masonry and/or wel-
ding and electrical connection operations using adequate equi-
pment for the job in complete respect of the accident-prevention
standards and regulations in force in the nation of installation.
The product must be electrically connected to a gate opera-
tor control board which is built-in in some LIVI 400 models; see
the instructions provided for such device for further information.
4.5.4 Use
The product is destined for incorporation in the assembly of
devices that comprise the gate's automatism. DEA System assu-
mes that it will always be used in compliance with the standards
and regulations in force.
All LIVI 400 models have an unlocking system; the working
of this system is the following: after unlocking the lock on the
handle (protected by a plastic cover) turn the lever in the direc-
tion shown in F9, page 32; the operator is now unlocked and,
if no obstructions hinder its movement, the gate can now move
freely. The opposite procedure, that is the rotation of the lever
up to the limit switch and the locking of the lock (remember to
protect the lock with the appropriate cover) returns LIVI 400 to its
normal working conditions.
4.5.5 Adjustment
Each LIVI 400 model is equipped with a limit switch whose
operation must be adjusted on site. DEA System supplies two
limit switch cams (see F4 page 30) which must be installed on
the gate rack and subsequently adjusted so as to guarantee the
gate functionality and safety distance both during opening and
closing. Some LIVI 400 models are equipped with mechanical
clutch to limit the pressure of the gate against an obstacle
obstructing its travel while opening or closing. Follow these
instructions to adjust it (see F6 page 31):
•disconnect power supply to the operator;
•hold firmly the motor shaft with a wrench while rotating the
grub screw with an Allen wrench (turn clockwise to increase
force, and turn counterclockwise to reduce force);
CAUSES / SOLUTIONS
L I V I 4 0 0
9

Capítulos

Tabla de contenido
loading

Tabla de contenido