Table B.2: Input and output currents, overload currents, carrier frequency and power losses specifications for: (50 °C / 122 °F
IP66 for motor integrate mountig and 40 °C / 104 °F IP66 wall mounting)
Tabla B.2: Especificaciones de corriente de salida y entrada, corrientes de sobrecarga, frecuencia de conmutación y
pérdidas para: (50 °C para convertidor montado sobre el motor y 40 °C IP66 montado en pared)
Tabela B.2:
Especificações de corrente de saída e entrada, correntes de sobrecarga, frequência de chaveamento e perdas
para: (50 °C IP66 para inversor montado no motor e 40 °C IP66 montado na parede)
Inverter
Convertidor
Inversor
MW500A02P1S2DB66...
MW500A02P9S2DB66...
MW500A03P4S2DB66...
MW500A04P3S2DB66...
MW500A06P0S2DB66...
MW500A01P3T4DB66...
MW500A01P6T4DB66...
MW500A02P0T4DB66...
MW500A02P6T4DB66...
MW500A04P3T4DB66...
MW500B05P2T4DB66...
MW500B06P5T4DB66...
MW500B10P0T4DB66...
MW500C14P0T4DB66...
MW500C16P0T4DB66...
Output Rated
Overload
Current
Currents
Corriente Salida
Corrientes de
Nominal
Sobrecarga
Corrente Nominal
Correntes de
de Saída
Sobrecarga
(Inom)
1 min
[Arms]
[Arms]
2.1
3.2
2.9
4.4
3.4
5.1
4.3
6.5
6
9.0
1.3
2.0
1.6
2.4
2
3.0
2.6
3.9
4.3
6.5
5.2
7.8
6.5
9.8
10
15.0
14
21.0
16
24.0
Rated Carrier
Frequency
Input Rated
Frecuencia de
Conmutación
Corriente
Nominal
de Entrada
Frequência de
Nominal
Chaveamento
Corrente
Nominal
Nominal de
Entrada
3 s
(fsw)
[Arms]
[kHz]
4.2
4
5.8
4
6.8
4
8.6
4
12.0
4
2.6
4
3.2
4
4.0
4
5.2
4
8.6
4
10.4
4
13.0
4
20.0
4
28.0
4
32.0
4
Appendix B / Anexo B
Inverter
Power Losses
Perdidas del
Convertidor
Current
Perdas do
Inversor
Surface
Mounting
Montaje en
Superfície
Montagem em
Superfície
[Arms]
[W]
5.1
49
7.1
49
8.3
49
10.5
49
14.6
65
1.2
45
1.5
45
1.8
45
2.4
45
4.0
65
4.8
109
6.0
109
9.2
168
12.9
220
14.7
270
MW500 | 129