Errors and possible rectification

Error message E0
Error message E1
Error messages E2 to E7
You can perform the rectification measures listed below yourself, making sure you fol-
low the safety instructions.
An E appears with a number in the display q:
1. No water boiler 6 inserted.
2. No water in water boiler 6.
3. The water boiler 6 is furred. ➥ Descale the water boiler 6 as described in
4. The water boiler 6 is defecti-
ve!
5. Appliance is defective!
Preheating phase longer than 180
sec.
1. The water boiler 6 is furred. ➥ Descale the water boiler 6 as described in
2. Seals are furred.
3. Seals are defective!
Appliance is defective!
Level indicator on water boiler 6 is difficult to read:
1. Level lamp is defective!
2. The water boiler 6 is furred. ➥ Descale the water boiler 6 as described in
The appliance does not heat up:
1. The water boiler 6 is incor-
rectly fitted.
2. The water boiler 6 is furred. ➥ Descale the water boiler 6 as described in
3. The water boiler 6 is defecti-
ve!
4. The cover 5 is open.
5. Water boiling coupling is defective!
Steam is escaping from housing:
1. Seals are furred.
2. Seals are defective!
3. Seals are missing.
➥ Mount the water boiler 6 as described in "Sec-
tion 4.3" page 58.
➥ Fill in water as described in "Section 4.3"
page 58. It may take several minutes for the er-
ror message E0 to extinguish.
"Section 6.5" page 73.
➥ Replace the water boiler 6.
➥ Switch off appliance and remove power plug f.
Contact Customer Service.
➥ Fill in warm water as described in "Section 4.3"
page 58.
"Section 6.5" page 73.
➥ Clean the seals as described in "Section 6.7.1"
page 74.
➥ Replace the seals as described in "Section 6.7.1"
page 74.
➥ Switch off appliance and remove power plug f.
Contact Customer Service.
➥ The appliance may remain in use.
Contact Customer Service.
"Section 6.5" page 73.
➥ Check the position of the water boiler 6 in the
appliance as described in "Section 4.3" page 58.
"Section 6.5" page 73.
➥ Replace the water boiler 6.
➥ Close the cover 5 as described in "Section 4.3"
page 58.
➥ Switch off appliance and remove power plug f.
Contact Customer Service.
➥ Clean the seals as described in "Section 6.7.1"
page 74.
➥ Replace the seals as described in "Section 6.7.1"
page 74.
➥ Fit the seals as described in "Section 6.7.1"
page 74.