Sharp R-CD1200M Manual De Operación página 17

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Air Filter Cycle
Air Filter Cycle can be changed from the factory setting
of 100 hours to 001-999 hours
* Suppose you want to set the cycle to 250 hours.
Procedure
CUSTOM
8 2
HELP
x 2
1 Press the CUSTOM HELP
pad twice within 2 seconds
and enter 8, 2.
SELECT
TIME
2 Press the SELECT TIME pad.
2
5
0
3 Enter desired time.
(Ex : Enter 2, 5, 0 for 250
hours).
START
4 Press the START pad to save settings.
STOP
CLEAR
5 Press the STOP/CLEAR pad to exit from the
Custom Help Function.
9. Selecting Operation in case of Magnetron Failure
Your oven has 2 magnetrons. In case of single magnetron
failure, the oven can be used until servicing by changing
settings to allow operation under single magnetron only.
However, check food carefully as additional cooking
time will be needed when operating with a single
magnetron.
CH91 : Your oven does not work when one magnetron
fails = Factory setting
CH92 : Your oven works even if one magnetron
fails.
To set magnetron failure options
Press the CUSTOM HELP pad twice within 2 seconds then
enter the numbers
9, 1 to stop operation when one magnetron fails
9, 2 to allow operation of one magnetron only
Press the START pad to save settings and the STOP/
CLEAR pad to exit from the Custom Help Function.
Display
After about 1 sec.
CHECK
EN-16
10. Multiplication Factor for Double/Triple Quantity
The multiplication factors of the double and triple
quantities for memory cooking are preset to 1.80
and 2.60. You can check or change the multiplication
factors.
* Suppose you want to know the multiplication
factor for double quantity with memory 1, and change
it to 2.00 in any Memory Input Method.
Procedure
CUSTOM
x2/x3
HELP
x 2
1 Press the CUSTOM HELP pad
twice within 2 seconds and
press the DOUBLE/TRIPLE
QUANTITY pad.
0
1
2 Enter memory number.
SELECT
TIME
3 Press the SELECT TIME pad.
2
0
0
4 Enter desired multiplication.
(Ex : Enter 2, 0, 0 for 2.00.)
START
5 Press the START pad to save
settings.
STOP
CLEAR
6 Press the STOP/CLEAR pad to exit from
the Custom Help Function.
Display
NO.
CHECK
NO.
CHECK
NO.
CHECK
After about 1 sec.
CHECK
NO.
CHECK
Tabla de contenido
loading

Este manual también es adecuado para:

Cd1800mCd2200mR-cd1800mR-cd2200m

Tabla de contenido