English
Message
2032 – Battery
temperature
Outside temperature
range
2040 – Battery
temperature
Outside temperature
range
2050 – Adapt mowing
plan
Extend active times
2060 – Mowing
completed
Press OK to release
2120 – Child lock
Child lock active
4001 – Internal fault
Outside temperature
range
4002 – Rollover
4003 – Hood lifted
Check hood, Then press
OK
4004 – Internal fault
Press OK to release
4005 – Internal fault
70
Possible Cause
Temperature in battery during charging too low
or too high.
Temperature in battery when starting mowing
operation too low or too high.
Active times have been shortened/deleted or
the mowing duration has been extended – the
stored active times are insufficient for the
necessary mowing operations.
Mowing in secondary area successfully
completed.
– Impact sensor triggered several times
consecutively.
– Robotic mower has been lifted during travel.
Temperature in battery or inside the machine
too low or too high.
See message 1000.
Hood has been lifted.
– Error in the program sequence.
– Power failure during automatic operation.
– Robotic mower is located outside the mowing
area.
See message 4004.
21 Troubleshooting Guide
Remedy
► Allow the robotic mower to warm up or cool
down.
► Allow the robotic mower to warm up or cool
down.
► Extend the active times or shorten the
mowing duration.
► Return the robotic mower to the mowing area
and dock to charge the battery.
► No action required if the impact sensor is not
triggered again, the message automatically
becomes inactive within max. 1 minute.
► Deactivate the child lock.
► Allow the robotic mower to warm up or cool
down.
► See message 1000.
► Check the hood and confirm the message by
pressing the OK button.
► Check the power supply to the docking
station.
Check the LED on the docking station. The
LED must glow red during operation.
► Return the robotic mower to the mowing area.
► Confirm message by pressing the OK button.
► See message 4004.
0478-131-3045-A