5
8
► Press and open the left clamping lever (8).
► Insert the stripped perimeter wire end (5) into the clamping
block as far as it will go.
► Close the clamping lever (8)
► Use a suitable tool to strip a = 0.236 in. (6 mm) from the
end of the right perimeter wire (6) and twist the perimeter
wire strands.
9
6
► Press and open the right clamping lever (9).
► Insert the stripped perimeter wire end (6) into the clamping
block as far as it will go.
► Close the clamping lever (9)
► Close the panel taking care not to pinch the power supply
cord or the perimeter wire.
28
a
6
► Close the cover of the cable duct (10).
► Check the routing of the perimeter wire. The two perimeter
wire ends must be routed as illustrated.
► Press the OK button on the control panel.
10 Installing the Robotic Mower
10
perimeter wire
Plug in the
docking station