Danger due to residual negative pressure or overpressure.
For residual overpressure: possible release of process fluids with risk of injury to the skin and eyes.
For negative pressure: possible drawing in of hair and clothing.
Disassemble the machine only after closing and draining the system connected to it.
The machine must be completely vented, cleaned and rendered inert before being sent to a service centre.
Due to the particular construction and operation of the machines, it is advisable to contact the FPZ
ATTENTION
service centres for this type of assistance.
14.3 REPLACING THE SOUND ABSORBING MATERIAL
When replacing the sound absorbing material in the silencers, proceed as follows (where foreseen):
Undo the screws (1)
Disconnect the silencer housings (2)
Remove the sound absorbing material from the silencer housings (3)
Recover the support mesh.
Replace the sound absorbing material
Remove sealant residue on the removed parts
Assemble in reverse order, making sure to restore the sealing with SYSTEM RS 01 between the parts that require it
1
14.4 LIFE OF BEARINGS
In normal operating conditions (values given in the "SPECIFICATIONS") it is advisable to have all the machine's bearings replaced by
FPZ personnel after 18000 hours or 3 years, whichever comes first.
14.5 OPERATION PROBLEMS
Problem
F
The unit does not
start
F
G
G
Insufficient or no air
G
flow
G
Insufficient or no
F
differential pressure
G
8
Divided as follows: F for functional fault and G for serious fault
FPZ-MI-R-MD-MOR-GOR-ATEX-15-R00
1
Cause
Incorrect electrical wiring.
Unsuitable supply voltage.
The impeller is stuck.
The suction filter is clogged.
Wrong frequency (for inverter powered units).
Profile of impeller blades modified (due to
deposits on the profile).
Wrong rotation direction.
Leak in the system
2 - 3
Cure
Have the electrical connection checked by the
Technician, referring to the diagram in the terminal box.
Check the power supply voltage. Tolerance of fixed
voltage value ± 10%.
Have the unit repaired by FPZ After-Sales Service.
Have the cartridge cleaned or replaced by the Technician.
Correct the frequency.
Have the impeller checked by FPZ After-Sales Service
Have the rotation direction reversed by the Technician ,
inverting the two power supply wires and leaving the earth
connection unchanged.
Find the leak and seal it.
48 / 111