12.5.1
ELECTRIC MOTOR REFERENCE STANDARD ATEX
The electric motors that power the machines are CE marked
ATEX 94/9/CE
LVD 2006/95/CE
EMC 2004/108/CE
12.5.2
CONNECTION
ATTENTION!
Connection to the grid must comply with the current regulations.
Make sure the mains voltage and frequency match the values given on the motor rating plate.
Danger due to electricity!
Before starting work on the unit or system, take the following precautions:
- make sure the machine is NOT powered;
- take steps to prevent the power from being reconnected;
The terminal box must not contain:
- foreign bodies;
- impurities;
- moisture.
The machines are supplied without control panel.
Wire sizes must be able to take maximum current absorbed by the electric motor.
The electric motor must be protected against the effects of short circuit, overload, phase failure and reconnection that can cause
overvoltages.
Before connecting to the grid, make sure to connect the earth wire to the respective electric motor terminal indicated by the
following symbol
.
Use the openings in the cable clamps to run the power cables inside the terminal box.
After making the terminal box connections, tighten the cable clamp to secure the cables.
The wiring in the terminal box must be carried out according to the desired connection (Δ, Υ) as shown in the diagrams below and
present in the terminal box:
3~
12.5.3
INVERTER POWERED ELECTRIC MOTOR
ATTENTION!
The performance of the unit may vary in case of power supply with inverter, and frequency or voltage different from the rated values. For
the performance of an inverter-powered unit with frequency or voltage different from the rated values, contact the FPZ After-Sales
Service.
Connect the electric motor thermal protectors, to protect the inverter-powered electric motor.
The power supply via inverter is always the responsibility of the installer, who must ensure compliance with the standards and the
installation procedures indicated by the inverter manufacturer.