Fig. 9
Injection unit stroke movement
NOTICE
• Note the max. stroke movement for injection.
• The max. stroke travel (traverse movement of the welding torch) should not exceed 6 mm.
• We recommend a maximum injection pulse of 3 s.
The injection pulse is reset when moving out of the injection unit.
• Use the adjusting screw (8) to adjust the volume of anti-spatter fluid per injection pulse.
• Fig. 8 Adjusting the anti-spatter fluid on page EN-16
• The anti-spatter fluid's residual oil from the injection unit is collected in the return flow bottle (6) and can be reused
once any dirt particles have been removed.
 Fig. 8 Adjusting the anti-spatter fluid on page EN-16
You can also activate the device manually via the cover to set the anti-spatter fluid dosage.
WARNING
Damage to the eyes
When injecting anti-spatter fluid, spray mist can form that can damage the eyes.
• Always wear safety goggles when manually adjusting the anti-spatter fluid.
• An injection pulse is activated by lightly pressing down on the cover.
• You can gauge the amount of the atomized anti-spatter fluid based on the spray mist produced.
• The injection pulse should be activated for max. 2 sec.
• Use the adjusting screw (8) to increase or reduce the amount of anti-spatter fluid.
 Fig. 8 Adjusting the anti-spatter fluid on page EN-16
NOTICE
• It only takes a small amount of anti-spatter fluid to achieve the desired effect.
BAL.0713.0 • 2019-02-11
Injection unit not activated
(max. stroke movement)
6 Commissioning
Injection unit activated