Specifications
Product
• fine powder to 12 mm (1/2")
Product Temperature
• -40 to 65 °C (-40 to 150 °F)
Ambient Temperature
• -40 to 65 °C (-40 to 150 °F)
Accuracy
• ± 1% of full scale
Repeatability
• ± 0.2%
Operating Range
• 0 to 0.5 t/h (0.6 STPH) min.
• 0 to 40 t/h (44 STPH) max (to suit application)
Construction
• painted mild steel flowguide and housing
• sensing plate (to suit application)
• ILE-37 sensing head
Classification
• NFPA code 8503
Approvals
• ILE-37: CSA Class I, Groups C and D, Class II Groups E, F, and G
Options
• Alumina Ceramic abrasion resistant sensing plate lining
EN-2
Milltronics C-40 – INSTRUCTION MANUAL
7ML19985DQ61