Three
Conductor
Wire
Connection
to
Range
(The 3-conductor
cord or cable must be replaced with
a 4-conductor
cord or cable where grounding through
the neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas
where local codes do not permit neutral grounding)
If local codes permit connection of the frame grounding
conductor to the neutral wire of the power supply cord
(Fig. 3):
1. Remove the
screws at the
lower end of the
rear wire access
panel, then lift
the lower part
of the access
panel to expose
range terminal
connection block
(Fig. 2).
Rear wire
access panel
Pressure regulator
location
Figure 2
Risk of fire or electrical
shock exists
if an incorrect
size range cord kit is used, if the
Installation
Instructions
are not followed,
or if the
strain relief bracket
is discarded,
Four
Conductor
Wire
Connection
to
Range
(mobile
homes)
1. Remove the screws at the lower end of the rear wire
access panel, then lift the lower part of the access
panel to expose range terminal connection block (Fig.
2).
2. Remove the three loose nuts on the terminal block
using a 3/8" nut driver or socket.
3. Remove the grounding strap from the terminal block
and from the appliance frame.
4. Connect the ground wire (green) of the power supply
cord to the frame of the appliance with the ground
screw, using the hole in the frame where the ground
strap was removed (see Figure 4).
5. Connect the neutral wire of the power supply cord to
the center silver-colored terminal of the terminal block,
and connect the other wires to the outer terminals.
Match terminal and power supply wires by color.
6. Replace the 3 nuts on the terminal block (see figure 4).
7. Replace the rear access panel using the screws
removed in step 1.
Direct
Electrical
Connection
to the
Circuit
Breaker,
Fuse Box
or Junction
Box
Terminal
2. Remove the 3 loose nuts on the terminal block using
3/8" nut driver or socket.
3. Connect the neutral white wire of the power supply
cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match terminal and power supply
wires by color.
4. Replace the 3 nuts on the terminal block (see figure 3).
5. Replace the rear access panel using the screws
removed on step 1.
Colored
Terminal
1-1/8" Dia.
Direct
Connection
Hole. Punch
out knockout
for 1-3/8" Dia.
Cord Kit
A user supplied
Terminal
Block
be installed at this
location.
To 240 V receptacle
NOTE: Be sure to remove the
f_
supplied grounding strap._
Figure 4
A strainrelief
supplied by
user must be
installed at this Iocatic
Figure 3
g
Strap
1-1/8" Dia. Direct
Connection Hole.
Punch out knockout
for 1-3/8" Dia.
Cord Kit Hole
4