Special Instructions
for appliances
installed
in the State
of Massachusetts:
This appliance
can only be installed
in the State of Massachusetts
by a Massachusetts
licensed plumber
or gas fitter. When using a flexible
gas connector,
it must not exceed 3 feet (36 inches) in
length.
A "T" handle
type manual
gas valve must be
installed
in the gas supply line to this appliance.
Model and Serial Number
Location
The serial plate is located at back of the appliance. Serial
Plate Location
A serial plate is located
on the lower trim and
visible when the oven
door is opened.
When ordering parts
for or making inquires
about your oven,
always be sure to
include the model and
serial numbers and a
lot number or letter
from the serial plate on
your oven.
Power Supply Cord Kit
The user is responsible for connecting the power supply
cord to the connection block located behind the back
panel access cover.
This appliance may be connected by means of
permanent "hard wiring" (flexible armored or
nonmetallic shielded copper cable), or by means of a
power supply cord kit. Use only a power supply cord kit
rated at 125/250 volts, 30 Amp and marked for use with
ranges. Cord must have either 3 or 4 conductors.
Terminals on end of wires must either be closed loop or
open-end spade lugs with upturned ends. Cord must
have strain relief clamp.
A 3-wire* or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on a
separate circuit fused on both sides of the line (time-
delay fuse or circuit breaker is recommended). DO NOT
fuse neutral. The fuse size must not exceed the circuit
rating of the appliance specified on the nameplate. Use a
circuit breaker and a power cord kit of 30 Amp.
*For mobile homes, new installations, recreational
vehicles, or areas where local codes do not permit
grounding through neutral, use a 4 conductor power
supply cord kit rated at 125/250 volts, 30 Amp and
marked for use with ranges (see Figure 4).
Junction Box or Wall ReceptacleLocation
Suggested
location
of the junction
box or wall
receptacle
is shown
in Figure
IA.
It can also be
located in the lower
left corner of the adjacent
right
cabinet
(see Figure
IB). If a service cord is used, the
wall receptacle should be located in accordance with the
dimensions in figures 1A and lB.
Center
Line of
Range
10"
(25.4 cm)
Line of
Range
Figure IA
Figure IB
/
Electrical
Connection
to the Range
This appliance is manufactured with the neutral terminal
connected to the range.
While connecting
range, do not
loosen the nuts which secure the terminal
block
to the range. Electrical
failure
or loss of electrical
connection
may occur.
Note: Refer to the wiring diagram at the end of this
manual.
Electrical
Shock
Hazard
• Electrical ground
is required
on this appliance.
• Do not connect
to the electrical
supply until
appliance
is permanently
grounded.
• Disconnect
power
to the circuit
breaker or fuse
box before
making the electrical
connection.
• This appliance
must be connected
to a
grounded,
metallic,
permanent
wiring
system,
or a grounding
connector
must be connected
to the grounding
terminal
or wire lead on the
appliance.
• Do not use the gas supply
line for grounding
the appliance.
Failure to do any of the above could result in a
fire, personal
injury or electrical
shock.
3