ENGLISH
Starting and testing of BIOX:
A. Fill the glass bottle of Biox with ClO
(follow instructions in the Biox package).
B. Fit the bottle into the red cap and fully screw .
C. Power on the electric component of Biox through the switch
D. Pick water through the supplied devices or the cock on the basin until
causing the Biox pump restart.
E. Hold down button "Manual dosing" until the dosing pump stops and the
"Dosing" yellow LED turns off (approx. 5 seconds).
F. Switch off Biox and then switch it on.
G. Repeat three times operations of points E and F.
H. Hold down button "Filling confirmation". The 6 red LEDs flash for about 5
seconds, then the LEds turn steady. Release the button. The 30‐day timer
has been reset .
I. Continue with the water picking for some dozens of seconds, then wait for
the machine stop.
Biox is now ready for use.
30
previously obtained through mixing
2