ACO LipuJet P-RB Instrucciones De Empleo página 94

Separador de grasa
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 205
LipuJet - P -RB / - RD / - RM / - RA / - RAP
Installation
Requirement: Suction pipe [ 9 ] must be in a
vertical position after installation.
The fixed coupling [ 2 ] and blind
coupling [ 3 ] are mounted on the
suction pipe [ 9 ] on delivery.
Loosen one screw joint
section (5).
Place the bracket [ 3 ] with the hole on
the longer section
bolt of the loosened screw joint
IMPORTANT Do not tighten the screw
joint with a tightening torque of 20 N . m
(6) until you have completed step (8).
Attach the pipe clamp [ 8 ] to the suction
pipe [ 9 ] (still movable) (7).
Step (8):
94/ 454
on the upper
over the stud
Slide the washer [ 4 ] onto the screw
[ 5 ] and insert the screw [ 5 ] through
the hole in the bracket [ 3 ] .
Slide the washer [ 6 ] onto the screw
[ 5 ] and tighten the nut [ 7 ] onto the
screw [ 5 ] .
Screw the screw [ 5 ] into the threaded
sleeve of the pipe clamp [ 8 ] . Tighten
the nut [ 7 ] by hand.
Align the pipe clamp [ 8 ] horizontally
and tighten the screw joints of the
pipe clamp [ 8 ] by hand.
.
5.
6.
7.
8.
loading

Este manual también es adecuado para: