of the appliance will flow to the floor or the carpet.
Continuous drainage. Fig. 11
1. Unscrew the drain cap and unplug the water plug.
2. Set the drainage pipe into the water outlet.
3. Connect the drainage hose to a bucket or big container.
Protection features:
Frost protection function
In cooling and dehumidification modes, if the temperature of the evaporator outlet
pipe is too low, the appliance will automatically enter protection mode to prevent
damage to the evaporator. The appliance will restart when the temperature is
restored to normal values.
Condensate water flooding protection function
When the water level exceeds the maximum level allowed by the safety buoy, the
appliance will switch off and activate the FULL indicator on the control panel. To
restart the device, the water inside the device will need to be drained through the
bottom drain plug (shown in detail in the drainage instructions section). Once the
water has been drained, the device will restart.
Automatic defrost
This air conditioner has an automatic defrost function.
Compressor protection function
To increase the service life of the compressor, it has a 3-minute delay booting
protection function after the compressor is turned off.
5. CLEANING AND MAINTENANCE
Turn off and unplug the device from the power supply before cleaning or repairing it.
Use a soft, dry (or slightly damp) cloth with some neutral cleaning agent to clean the
product's outside and prevent the accumulation of dust and dirt.
If the product is not going to be used for a long time, store it in a safe and well-
ventilated place.
Do not use detergent, scouring pads, chemically-treated cloths, petrol, benzene,
alcohol, thinner, or other solvents, as these can scratch and damage the tank and