INSTALLING AUXILIARY BATTERY HOLDER KIT
`
Disconnect vehicle high voltage battery prior to installing the auxilliary battery holder
kit. Failure to comply creates a high risk of death, serious injury and damaged equip-
ment.
1. Disconnect vehicle high voltage battery by
following instructions in Ford SVE Bulletin
P-034R1.
2. Remove 12V service battery
access panel and D-rings from
the frunk tub wall. Retain access
panel, D-rings, and cap screws
for later reinstallation
(FIG. 19-1).
SERVICE BATTERY
LIFT CORPORATION Sht. 19 of 76 DSG#
ACCESS PANEL
WARNING
!
FRUNK TUB
WALL
REMOVING BATTERY ACCESS PANEL
M-24-01
Rev. - Date: 05/07/24
D-RING
TORX CAP SCREW
(2 PLACES)
(2 PLACES)
FIG. 19-1