Installation of Heater

Inside of Structure
FIG. 4
500 GALLON (1892 litre)
GAS SUPPLY
(MINIMUM)
MINIMUM SAFE DISTANCE FROM
GAS SUPOPLY TO HEATER MUST
CONFORM TO LOCAL CODES
DISTANCE FROM HEATER TO SIDE WALL MUST
COMPLY WITH LOCAL CODES, AND BE ACCORDING
TO MANUFACTURER'S REQUIREMENTS
Outside of Structure
(Air distribution accessories -
not supplied with heater)
A. Flex Duct Kit
Part Number: 22835 (18 in. x 12 ft. / 46 cm x 3.65 m)
1. Extend duct kit to 12 feet/3.6 meter length.
2. Mount duct to blower outlet of heater by inserting tabs
on duct adapter into vertical and horizontal slots located
at top and sides of blower outlet. See Fig. 5. Push down
on duct adapter to secure adapter into slots. See below
for typical installation of heater located at exterior.
A maximum of three (3) 12 ft. x 18 in. (3.65 m x 46 cm)
ducts can be used per heater. DO NOT attach an end
diffuser when using three ducts. See Fig. 6 for typical
installation.
FIG. 5
SLOTS
TAB

DUCT KIT

SIDE WALL
MINIMUM SAFE DISTANCE FROM
TOP, SIDES, AND BACK OF HEATER
TO COMBUSTIBLES IS 1 FOOT (0.3m)
MINIMUM SAFE DISTANCE FROM
BLOWER OUTLET TO COMBUSTIBLES
IS 6 FEET (1.83m)
DUCT ADAPTER
WITH TABS
Owner's Manual • Premier 350
Premier Ductable Heaters
FIG. 6
TENT DRAPED OVER DUCT
500 GALLON
(1892 LITRE)
GAS SUPPLY
(MINIMUM)
MINIMUM SAFE DISTANCE FROM GAS
SUPPLY TO HEATER MUST CONFORM
TO LOCAL CODES
DISTANCE FROM HEATER TO SIDE WALL MUST
COMPLY WITH LOCAL CODES, AND BE ACCORDING
TO MANUFACTURER'S REQUIREMENTS
B. End Diffuser
Part Number: 23189
Use only one duct (12 ft. /3.7 m x 18 in./ 48 cm) per
heater when using an end diffuser.
1. Loosen screw on duct clamp so clamp is easily
positioned over ribs at end of fl exible duct.
2. Slide duct adapter into duct end. Duct adapter tabs
must be facing away from duct and are located at 3,
9 and 12 o'clock positions. See Fig. 7.
3. Tighten screw clamp so adapter is held securely-
within duct.
4. Insert tabs of adapter into slots on air diffuser back.
5. Push down on adapter so tabs are seated fi rmly to
air diffuser.
6. Locate diffuser under side wall. See Fig. 8.
FIG. 7
TABS
SIDE WALL
TENT DRAPED
OVER DUCT
DUCT KIT
CLAMP
DUCT ADAPTER
DIFFUSER
15