GROUNDING INSTRUCTIONS
This product must be grounded. In the event of an electrical short circuit,
grounding reduces the risk of electric shock by providing an escape wire for the
electric current. This product is equipped with a cord having a grounding wire with an
appropriate grounding plug. The plug must be plugged into an outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
WARNING - Improper installation of the grounding plug can result in
a risk of electric shock.
If repair or replacement of the cord or plug is necessary, do not connect the green
grounding wire to either flat blade terminal. The wire with insulation having a green
outer surface with or without yellow stripes is the grounding wire and must be
connected to the grounding pin.
Check with a qualified electrician or serviceman if the grounding instructions are not
completely understood, or if you are in doubt as to whether the product is properly
grounded. Do not modify the plug provided. If the plug will not fit the outlet, have the
proper outlet installed by a qualified electrician.
This product is for use on a nominal 120 volt
circuit and has a grounding plug that looks like
the plug illustrated below. Make sure that the
product is connected to an outlet having the
same configuration as the plug. No adapter
should be used with this product.
IMPORTANT ELECTRICAL INFORMATION
Use only a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot
receptacle that will accept the plug on the product. Make sure your extension cord is
in good condition. When using an extension cord, be sure to use one heavy enough to
carry the current your product will draw. An undersized cord will cause a drop in line
voltage resulting in loss of power and overheating. A 14 gauge or 12 gauge cord is
recommended. If an extension cord is to be used outdoors, it must be marked with the
suffix W-A after the cord type designation. For example, a designation of SJTW-A would
indicate that the cord would be appropriate for outdoor use.
SAFETY HAZARDS
Read all safety information before operating the equipment. Save
these instructions.
Indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
To reduce the risks of fire or explosion, electrical shock and the
injury to persons, read and understand all instructions included in
this manual. Be familiar with the controls and proper usage of the
equipment.
HAZARD: EXPLOSION OR FIRE
Solvent and paint fumes can explode or ignite, causing property damage
and/or severe injury.
PREVENTION:
Exhaust and fresh air introduction must be provided to keep the air within the work
area free from accumulation of flammable vapors.
Avoid all ignition sources such as static electricity sparks, open flames, pilot lights,
hot objects, cigarettes, and sparks from connecting and disconnecting power cords
or working light switches.
Fire extinguishing equipment must be present and in working order.
Do not use materials with a flashpoint below 100˚ F (38˚ C). A fluid's flashpoint is
the temperature at which vapors from the fluid could ignite if exposed to a flame or
spark. Consult your paint supplier for information about a fluid's flashpoint.
Keep the unit in a well ventilated location away from the work area. The pump
contains arcing parts which emit sparks.
HAZARD: HAZARDOUS VAPORS
Paints, solvents, insecticides, and other materials may be harmful if
inhaled, causing severe nausea, fainting, or poisoning.
PREVENTION:
Use a respirator or mask whenever there is a chance that vapors may be inhaled. Read
all instructions with the mask to insure that it will provide the necessary protection
against the inhalation of harmful vapors.
HAZARD: GENERAL
This product can cause severe injury or property damage.
PREVENTION:
Read all instructions and safety precautions before operating any equipment. Never
leave the unit running while unattended. Unplug whenever not in use.
Never immerse the unit into any liquid.
2
Grounded Outlet
Grounding Pin
Cover for grounded outlet box
Comply with all appropriate local, state and national codes governing ventilation,
fire prevention, and operation.
This paint roller system is designed to be used with authorized parts only. When
using this system with parts that do not comply with the minimum specifications and
safety devices of the system manufacturer, the user assumes all risks and liabilities.
Before each use, check all hoses for cuts, leaks, abrasion or bulging of cover or
damage or movement of couplings. If any of these conditions exist, call Product
Support.
i
Additional warnings are contained on the tag molded to the
electrical cord of the unit. Be sure to read this tag before operating
the unit.
WARNING! CALIFORNIA PROPOSITION 65 WARNING
This product can expose you to chemicals including lead, which are known to the State
of California to cause cancer, birth defects, or other reproductive harm.
For more information go to www.P65warnings.ca.gov.
F
DIRECTIVES SUR LA MISE À LA TERRE
Ce dispositif doit être mis à la terre. En cas de court-circuit, ce procédé permet
de réduire le risque d'un choc électrique en fournissant un parcours d'évacuation pour le
courant. Ce produit est équipé d'un cordon comportant un fil de mise à la terre, et muni
d'une fiche appropriée. Cette fiche doit être connectée dans une prise adéquatement
installée et mise à la terre selon les codes et règlements en vigueur.
MISE EN GARDE! Une installation inadéquate de la fiche de mise à
la terre risque de provoquer un choc électrique.
S'il est nécessaire de réparer ou de remplacer le cordon ou la fiche, ne pas connecter
le fil de mise à la terre vert à aucune des bornes à broches plates. Le fil comportant un
isolant de couleur verte, avec ou sans lignes jaunes, est le fil de mise à la terre devant
être connecté à la broche de mise à la terre.
Il est recommandé de consulter un électricien qualifié ou un technicien si les directives
sur la mise à la terre ne sont pas entièrement comprises, ou si l'on n'est pas sûr que le
produit soit correctement mis à la terre. Ne pas modifier la fiche. Si la fiche ne peut être
insérée dans la prise, demander à un électricien qualifié d'installer la prise appropriée.
Ce produit doit être utilisé sur un circuit d'une
tension nominale de 120 volts et comporte une
fiche de mise à la terre semblable à celle illustrée
ci-dessous. Veuillez-vous assurer que le produit
est connecté à une prise électrique ayant la
même configuration que la fiche mâle. Ne pas utiliser d'adaptateur avec ce produit.
INFORMATIONS IMPORTANTES SUR LE SYSTÈME ÉLECTRIQUE
Utilisez seulement une rallonge électrique trifilaire pourvue d'une prise avec mise à
la terre (trois tiges) et d'une connexion femelle à trois trous convenant au cordon de
l'appareil. Assurez-vous que la rallonge électrique est en bon état. Lorsque vous utilisez
une rallonge électrique, assurez-vous qu'elle a un calibre assez élevé pour transmettre
le courant nécessaire au fonctionnement de l'appareil. L'utilisation d'une rallonge de
calibre trop faible entraîne une chute de tension sectorielle se traduisant par une perte
de courant et une surchauffe de l'appareil. On recommande des fils de calibre 14 ou 12.
Si vous devez utiliser une rallonge à l'extérieur, la mention W-A doit y figurer suivant
la désignation du type de rallonge. Par exemple, SJTW-A représente une rallonge
appropriée pour une utilisation à l'extérieur.
RISQUES D'ACCIDENTS
Lire toutes ces consignes avant d'utiliser l'appareil.
consignes.
Indique une situation à risque, laquelle, si elle n'est pas évitée, peut
entraîner des blessures graves, voire la mort.
Pour réduire les risques d'incendie ou d'explosion, de choc électrique
et de blessure, vous devez lire et comprendre les directives figurant
dans ce manuel. Familiarisez-vous avec les commandes et l'utilisation
adéquate de l'équipement.
RISQUE D'EXPLOSION OU D'INCENDIE
Les vapeurs inflammables, comme les vapeurs de solvant et de peinture,
dans un espace de travail peuvent s'enflammer ou exploser.
PRÉVENTION :
On doit s'assurer que la zone de travail est libre de vapeurs inflammables en
permettant l'arrivée d'air frais pour remplacer l'air vicié.
Évitez de créer des sources d'allumage comme l'électricité statique, la flamme à l'air
libre, la flamme pilote, les objets brûlants, les cigarettes et les étincelles en branchant
et débranchant un cordon d'alimentation ou en actionnant l'interrupteur d'un
projecteur de travail.
Ayez toujours un extincteur en état de fonctionnement à portée de la main.
N'employez pas de matières dont le point d'éclair est inférieur à 38 ˚C (100 ˚F). Le
Prise tri laire
Broche de mise à la terre
Plaque murale de la prise