6. Safety-related characteristic values
6. Safety-related characteristic values
DANGER!
Danger to life due to loss of explosion protection
The non-observance of the instructions for use in hazardous areas can
lead to the loss of the explosion protection.
Adhere to the following limit values and instructions.
Only use the listed batteries, see chapter 4.2.1 "Approved batteries".
Only replace the batteries outside the hazardous area, see chapter
4.2.2 "Battery replacement".
Permissible temperature ranges
Ambient temperature range (T
Max. medium temperature range (T
Battery supply
Rated voltage (3 x AA-sized batteries)
Max. voltage (spark ignition)
High-frequency output with Bluetooth
Output frequency
Nominal output power
Max. output power (under fault conditions for "ia")
WIKA additional operating instructions, model CPG1500 (Ex i)
)
a
)
m
®
-10 ≤ T
≤ +50 °C
a
-10 ≤ T
≤ +50 °C
m
DC 4.5 V
DC 4.95 V
2,400 ... 2,500 MHz
10 mW
490 mW