• Do not replace the fuse with a wire or other material.
• Do not connect the ground wire to a gas pipe or water pipe,
since an improper grounding can cause an electric shock.
• Do not place plants or animals directly in the airflow path of the
air conditioner as it could hurt them.
• Do not unplug the power plug or turn off the circuit breaker
when this appliance is working.
• Do not install the air conditioner where there may be gas leaks
or flammable substances.
2. MAINTENANCE
Careful maintenance and early inspection can extend the life of
the air conditioner and reduce electricity bills.
Attention!
1. Turn off the air conditioner with the remote control and unplug
it from the mains before performing service and maintenance.
2. Do not stand on unstable objects when cleaning or maintaining
the air conditioner, otherwise it may cause injury.
3. Do not touch the metal part of the air conditioner body when
removing the front panel, otherwise it may cause injury.
4. Do not clean the device with water as this may cause an
electric shock.
5. Do not clean the remote control with water.
6. Do not clean the appliance with alcohol, benzine, oil or polish.
7. Please do not wipe the device using excessive force, otherwise
the front panel may fall off.
8. Do not clean the front panel or remote control with metal
brushes since this may damage the surface.
CLEANING THE FRONT PANEL AND REMOTE CONTROL
If the dirt cannot be removed, wipe it with a warm damp cloth
(soaked in warm water below 40 ºC)
MAINTENANCE WHEN THE APPLIANCE WILL NOT BE USED
FOR A LONG TIME
1. Leave the air conditioner working for 3-4 hours so it can dry
inside.
2. Turn it off using the remote control and unplug the power plug.
3. Clean the air filter.
4. Remove the batteries from the remote control.
FILTER CLEANING
Fig. 1
1. Open the front panel.
2. Lift the protruding part, then pull it down and remove the air
filter.
3. Clean it with a vacuum cleaner or water. If the air filter is very
dirty, clean it with warm water and a mild soap or detergent,
and then let it dry in the shade.
4. Reinsert the air filter and close the front panel.
6
Fig. 1. 1
Fig. 1.2
Fig. 2
3. PRODUCT DESCRIPTION
PROTECTION FUNCTIONS
Protection functions can extend the life of the air conditioner and
provide a more comfortable airflow.
• Delayed start protection for the compressor
The compressor will start working at least 3 minutes (5 minutes
in heating mode) after the appliance is turned off to maintain
the pressure balance of the refrigeration system.
Attention!
The air filter should be cleaned at least once every two weeks,
otherwise the heating or cooling capacity will be reduced.
Do not clean the air filter with a metal brush as this could damage
it.
OBSERVATIONS:
It will take 1 minute for the compressor to run after the unit is
turned on for the first time.
• Defrost
The outdoor heat exchanger may freeze if the outdoor temper-
ature is low and the humidity is high. In this case, the automatic
defrost will work for 3-10 minutes, the pause indicator will be on
and the indoor and outdoor fans will not work.
• HEAT overload protection (not available for cooling-only type
of air conditioner). When the indoor pipe temperature is too
high, the air conditioner enters in heating overload protection
mode, and the indoor fan speed is automatically set to a higher
speed. The outdoor fan and compressor can be stopped in this
mode. When the indoor pipe temperature drops to a nominal
value, the air conditioner exits overload protection mode and
the indoor fan motor returns to its normal state.
• Residual heat function (not available for cooling-only type of
air conditioner)
The indoor fan keeps running at low speed for 80 seconds when
the air conditioner stops in heating mode.
• Airflow Cooling Test (not available for cooling-only type of air
conditioner)
In the first minutes of heating operation, the PAUSE light will
switch on, the internal fan does not work and the flaps cannot
be controlled. Approximately 5 minutes later, the air conditioner
sends a flow of hot air, and the PAUSE light will switch off.
• Anti-freezing function
In order to prevent the indoor heat exchanger from freezing
during cooling and drying, the compressor or outdoor fan may
stop working and the indoor fan speed will automatically adjust
to a higher speed.
• Auto reset (optional)
The unit memorizes the operating mode, airflow setting,
temperature setting, etc., which means that in case of a power
outage when the unit is running, it will automatically return to
the same operating condition when energy is restored.
• Anti-drip
During cooling and dehumidifying operations, the louver flaps'
position can be automatically changed to avoid dripping.
REMARKS:
1. HEAT, AUTO function and display are not available for cool-
ing-only type air conditioner.
2. If users want to cool or warm up the room air quickly, they can
press the 'turbo' button in cooling or heating mode, and the air
conditioner will run in power function. If the 'turbo' button is
pressed again, the air conditioner will exit power function.
3. The above remote control illustration is for reference only, as
it may be slightly different from the actual product you selected.
loading

Este manual también es adecuado para:

Bac8698Bac8699