4 INSTALLATION
4.4
Mains supply
NOTE!
Mains supply requirements
High power equipment may, due to the primary current drawn from the mains
supply, influence the power quality of the grid. Therefore connection restrictions
or requirements regarding the maximum permissible mains impedance or the
required minimum supply capacity at the interface point to the public grid may
apply for some types of equipment (see technical data). In this case it is the
responsibility of the installer or user of the equipment to ensure, by consultation
with the distribution network operator if necessary, that the equipment may be
connected.
Make sure that the welding power source is connected to the correct supply voltage and that
it is protected by the correct fuse rating. A protective earth connection must be made in
accordance with regulations.
Table 1. Recommended fuse sizes and minimum cable area Warrior 400i CC/CV
Mains voltage
Mains cable area
I
eff
Fuse
anti-surge
type C MCB
Table 2. Recommended fuse sizes and minimum cable area Warrior 500i CC/CV
Mains voltage
Mains cable area
I
eff
Fuse
anti-surge
type C MCB
0221323
Warrior 400i CC/CV
380 V 3~ 50/60 Hz
2
4C 8Awg / 4G 6mm
22 A
25 A
25 A
Warrior 500i CC/CV
380 V 3~ 50/60 Hz
2
4C Awg / 4G 6mm
29 A
35 A
32 A
- 59 -
440 V 3~ 50/60 Hz
2
4C 8Awg / 4G 6mm
21 A
25 A
25 A
440 V 3~ 50/60 Hz
2
4C 8Awg / 4G 6mm
27 A
35 A
32 A
460 V 3~ 50/60 Hz
2
4C 8Awg / 4G 6mm
21 A
25 A
25 A
460 V 3~ 50/60 Hz
2
4C 8Awg / 4G 6mm
26 A
35 A
32 A