1. GENERAL INFORMATION
Carefully read and follow the instructions in the manual. Keep this manual for future use and maintenance. Pay
attention to the TRIMMER configuration and/or to the WI-FI settings, performance data (see "Technical Data") and
installation instructions. Improper use or incorrect operation/installation could damage the system as well as
objects and/or persons.
2. SAFETY
This installation manual is only intended for professional personnel. Installation, electrical connections and
adjustments must be carried out respecting Good Technique and in compliance with the current regulations. Read
the instructions carefully before starting to install the product. Incorrect installation can be a source of danger.
Packaging materials (plastic, polystyrene, etc.) must not be dispersed in the environment and must not be left
within the reach of children as they are potential sources of danger. Before starting the installation check the
integrity of the product.
If the power cord is damaged, it must be replaced by the manufacturer, by its technical assistance service or in any
case by a person with similar qualification in order to prevent any risk.
Do not install the product in an explosive environment and atmosphere: the presence of flammable gases or fumes
constitute a serious safety hazard.
Before installing the motor, make all the structural changes relating to the construction of safety measures and the
protection or segregation of all crushing, shearing, conveying and danger zones in general. Check that the existing
structure has the necessary strength and stability requirements. The drive manufacturer is not responsible for
failure to respect Good Technique in the construction of the windows to be motorised, as well as for any deformations
that could occur during use. Apply the warnings required by current regulations to identify hazardous areas.
Check that the electricity distribution network is not the "site" type but is under dedicated cabins. In the event of
uncertainty or the absence of (certain) information, also ensure:
-
dedicated isolation transformers;
-
circuit breakers suitable for the required voltage load;
-
surge arresters.
Before connecting the power supply, make sure that the plate data correspond to those of the electrical distribution
network. Provide an omnipolar switch/disconnector on the power supply network with an opening distance of the
contacts equal to or greater than 3 mm. Check that there is a suitable circuit breaker and overcurrent protection
upstream of the electrical system. When required, connect to an effective earthing system performed according to
the current safety regulations of the country in which the actuator is installed. Before carrying out any intervention
(installation, maintenance and repair) disconnect the power supply before acting on the equipment. To ensure
effective separation from the network, it is necessary to install an approved bipolar button with "operator present"
operation.
The 24 Vdc low voltage actuators must be powered by dedicated class II approved power supplies (NO
TRANSFORMERS) (double safety insulation) with an output voltage of 24 Vdc - 27Vdc. Using the 24Vdc version the
cable must have a suitable section, calculated based on the distance between the power supply and the actuator in
order to avoid voltage drops or losses.
The appliance is not intended for use by persons (including children) whose physical, sensory or mental capabilities
are impaired or who lack experience or knowledge unless they have been able to benefit, through the intermediary
of a person responsible for their safety, from surveillance or instruction concerning use of the appliance. Children
should be supervised to ensure that they do not play with the appliance.
The STAR 25 line actuators are intended solely and exclusively for the use for which they were designed and the
manufacturer cannot be held responsible for damage due to improper use. The actuator is intended exclusively for
internal installation to open and close top hung outward opening, bottom hung inward opening or hinged windows.
Any other use is not recommended unless previously approved by the manufacturer. The actuator must be installed
following the instructions in this manual. Failure to comply with these recommendations could compromise safety.
Any service and control device of the actuator must be produced according to the regulations in force and comply
with the relevant regulations issued by the European Community.
If the actuator is installed on a window located at a height of less than 2.5 m from the floor and in buildings (public
and non-public) where the intended use is not clear, the actuator must only and exclusively be operated by a