WIKA DPGS40TA Manual De Instrucciones página 6

Manómetro diferencial con microswitch, con prueba de componentes
Ocultar thumbs Ver también para DPGS40TA:
Idiomas disponibles

Idiomas disponibles

2. Safety
2.2 Additional instructions for operation as a flow limiter
This chapter only applies to model DPGS40TA.100-*S*.
Regulations for pressure equipment
EN
Instrument type: Safety accessory
Media: Liquid or gaseous, group 1 (hazardous)
For maximum allowable pressure PS, see chapter 2.6 "Labelling, safety
marking"
Volume of wetted parts: < 0.1 L
2.2.1 Test principles for flow component test
VdTÜV code of practice "Flow 100", edition 2017-03-15, in conjunction with
VdTÜV code of practice "General guidelines 002", edition 2019-02-22
Essential safety requirements of directive 2014/68/EU from 15 May 2014
(Pressure Equipment Directive)
2.2.2 Restrictions
1.
For the switch contacts, dimension and install a fuse with 0.6 times the nomi-
nal current.
2.
The maximum current load of the switch contacts must not exceed AC 1.4 A
and DC 0.4 A.
2.2.3 Comments
1.
Use as a limiter. Connect an external interlock downstream as a limiter,
which fulfils the requirements in accordance with VdTÜV code of practice
"Flow 100", edition 2017-03-15, sections 3.9, 5.4.1 and 5.6.
2.
Follow the manufacturer's commissioning instructions.
3.
IP ingress protection at supply line gland. Take care that the supply cable
used has a diameter that does not reduce the IP ingess protection of the
cable gland.
4.
Follow the manufacturer's installation instructions.
2.2.4 Special responsibilities for testing before commissioning
1.
The requirements of sections "2.2.2 Restrictions" to "2.2.4 Special responsibil-
ities for testing before commissioning" shall be reviewed.
2.
Carry out functional test of the installed instruments. For limiters carry out
additional control of the downstream interlock circuit.
3.
Follow the general technical regulations for pressure measuring instruments
(e.g. EN 837-2 "Selection and installation recommendations for pressure
gauges").